Skip links

Product List

Product List

Part NumberDescription
3 230 9178-001Fixation set (4 pieces) for Web panel
with embedded Micro-Browser
3 230 9178-002Fixation set (6 pieces) for Web panel
with embedded Micro-Browser
4 104 7420 0Lead sealing cap for energy meters
AAD1 and ALD1
4 104 7485 0Lead sealing cap for energy meters
AAE1, AAE3, ALE3 and AWD3
4 104 7493 0Cover for PCD3.M5xxx and ..M6xxx
4 104 7502 0Slot cover for unused PCD3 I/O slots
(neutral – without SBC logo)
4 104 7515 0Slot cover for unused PCD3 I/O slots
(with SBC logo)
4 104 7719 0Cover for PCD2.M5x40 without SBC logo
(with neutral front cover)
4 104 7720 0Cover for PCD2.C2000 without SBC logo
(with neutral front cover)
4 104 7758 0Cover for PCD2.C1000 without SBC logo
(with neutral front cover)
4 104 7759 0Cover for PCD1.M2xxx without SBC logo
(with neutral front cover)
4 121 4910 0Additional fixation set (4 pieces) for hollow
(cavity) in-wall mounting of the MB web panel 5.7″
4 310 8686 0Pre-printed adhesive strips for snap on
holder 4 329 4819 1
4 310 8723 0Labelling clip set containing
– 10 snap on transparent label holders (label clip)
– 2 sheets of neutral pre-cut inscription labels (DIN A4)
4 310 8750 0Spare part for Web panel PCD7.D457VTCF
True brushed aluminum front overlay
4 310 8755 0Spare part for Web panel PCD7.D457VTCF
Black and sparkling front overlay
4 310 8756 0Spare part for Web panel PCD7.D457VTCF
Front overlay with mirror effect
4 329 4819 1Snap on holder for module marking
Set of 10 pieces
4 405 4847 0Plug-in screw terminal block 10-pole,
labelling 0…9 or for I/O module
4 405 4869 0Plug-in screw terminal block 14-pole,
for PCD2.A250 module
4 405 4916 0Plug-in screw terminal block 10-pole,
labelling 0…9
4 405 4917 0Plug-in screw terminal block 10-pole,
labelling 10…19
4 405 4918 0Plug-in screw terminal block 10-pole,
labelling 20…29
4 405 4919 0Plug-in screw terminal block 10-pole,
labelling 30…39
4 405 4920 0Plug-in screw terminal block 10-pole,
labelling 40…49
4 405 4921 0Plug-in screw terminal block 10-pole,
labelling 40…49
4 405 4933 0Plug-in I/O spring terminal block,
6-pole up to 2.5 mm2, labelled 1 to 6,
for Web panel with embedded Micro-Browser
4 405 4934 0Plug-in I/O spring terminal block,
8-pole up to 1.5 mm2, labelled 1 to 8,
for manual control module PCD3.W800,
connector type “J”
4 405 4936 0Plug-in I/O spring terminal block,
12-pole up to 1.5 mm2, labelled 1 to 12,
for manual control module PCD3.A810,
connector type “F”
4 405 4952 0Plug-in screw terminal block,
2-pole up to 2.5 mm2 (orange block)
for PCD3.C200 and PCD3.T760
4 405 4954 0Plug-in I/O spring terminal block,
10-pole up to 2.5 mm2, labelled 0 to 9,
for modules with 4, 6 or 8 I/Os,
connector type “A”
4 405 4956 0Plug-in I/O spring terminal block,
2×12-pole up to 1.0 mm2, labelled 0 to 23,
for modules with 16 I/Os or relay module ..A251,
connector type “C”
4 405 4995 0Plug-in spring terminal block,
8-pole up to 2.5 mm2 (orange block)
for PCD3.M2/..M3/..M5/.M6 and PCD3.T66x
4 405 4998 0Plug-in I/O spring terminal block,
14-pole up to 1.5 mm2, labelled 0 to 13,
for complex modules (e.g. weighing modules),
connector type “E”
4 405 5027 0Plug-in I/O spring terminal block,
4-pole up to 2.5 mm2, labelled 1 to 4,
for light and shade control module PCD3.A860,
connector type “G”
4 405 5028 0Plug-in I/O spring terminal block,
2×3-pole up to 1.0 mm2, labelled 1 to 6,
for light and shade control module PCD3.A860,
connector type “H”
4 405 5048 0Plug-in spring terminal block,
2×5-pole up to 1.0 mm2 (orange block),
labelled 0 to 9, also for PCD2.G200,
connector type “K”
4 405 5054 0Plug-in spring terminal block,
2×5-pole up to 1.0 mm2 (black block),
also for PCD2.G200
4 405 5055 0Plug-in screw terminal block 10-pole,
labelling 30…39
4 405 5056 0Plug-in screw terminal block 10-pole,
labelling 29…20
4 405 5057 0Plug-in screw terminal block 10-pole,
labelling 19…10
4 405 5066 0Plug-in I/O spring terminal block with LED,
only for digital I/O 24 VDC (transistors),
10-pole up to 1.5 mm2
4 405 5079 0Plug-in I/O spring terminal block with LED,
only for digital I/O 24 VDC (transistors),
3x 10-pole (3 wire connection) up to 1.5 mm2
4 405 5087 0Plug-in screw terminal block 9-pole,
labelling 11…19
4 405 5088 0Plug-in screw terminal block 10-pole,
labelling 20…29
4 405 5089 0Plug-in screw terminal block 11-pole,
labelling 0…10
4 405 5109 0Plug-in screw terminal block 9-pole
for PCD2.F2400
4 507 4817 0Lithium battery for PCD processor units
(RENATA button type CR 2032)
4 639 4898 0Battery carrier module
for PCD2.M4xxx and PCD3.M5xxx/..M6xxx
AAD1D5F10KR3A00Single-phase energy meter (7-digit)
S0 pulse output = 1’000 pulses/kWh
Imax = 32 A, according to MID directive
AAE1D5F10KR3A00Single-phase energy meter (7-digit)
S0 pulse output = 1’000 pulses/kWh
Imax = 65 A, according to MID directive
AAE3D5F10PR3A00Three-phase energy meter (7-digit)
S0 pulse output = 100 pulses/kWh
Imax = 65 A, 1 tariff, according to MID directive
AAE3D5F11PR3A00Three-phase energy meter (7-digit)
S0 pulse output = 100 pulses/kWh
Imax = 65 A, 2 tariffs, according to MID directive
ALD1B5F10KA3A00Single-phase two-way energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 32 A
according to MID directive
display of active power, voltage and current
ALD1B5FD00A3A00Single-phase two-way energy meter with LCD display
Modbus interface, Imax = 32 A
display of active power, voltage and current
according to MID directive
ALD1B5FS00A3A00Single-phase two-way energy meter with LCD display
S-Bus interface, Imax = 32 A
display of active power, voltage and current
according to MID directive
ALD1D5F10KA3A00Single-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 32 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALD1D5F10KB3A00Single-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 32 A, 1 tariff, according to MID directive
ALD1D5FD00A3A00Single-phase energy meter with LCD display
Modbus interface, Imax = 32 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALD1D5FD00A3A44Single-phase energy meter with LCD display
Modbus interface, parity 8N1, Imax = 32 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALD1D5FM00A3A00Single-phase energy meter with LCD display
M-Bus interface, Imax = 32 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALD1D5FS00A3A00Single-phase energy meter with LCD display
S-Bus interface, Imax = 32 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALE3B5F10KC3A00Three-phase two-way energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 65 A
display of active power, voltage and current
display without main power (backup)
according to MID directive
ALE3B5FD00C3A00Three-phase two-way energy meter with LCD display
Modbus interface, Imax = 65 A
display of active power, voltage and current
according to MID directive
ALE3B5FM00C3A00Three-phase two-way energy meter with LCD display
M-Bus interface, Imax = 65 A
display of active power, voltage and current
according to MID directive
ALE3B5FS00C3A00Three-phase two-way energy meter with LCD display
S-Bus interface, Imax = 65 A
display of active power, voltage and current
according to MID directive
ALE3D5F10KA3A00Three-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 65 A, 1 tariff
display of active power, voltage and current
according to MID directive
ALE3D5F10KB3A00Three-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 65 A, 1 tariff
according to MID directive
ALE3D5F11KC3A00Three-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 65 A, 2 tariffs
display of active power, voltage and current
display without main power (backup)
according to MID directive
ALE3D5FD10C3A00Three-phase energy meter with LCD display
Modbus interface, Imax = 65 A, 2 tariffs
display of active power, voltage and current
according to MID directive
ALE3D5FD10C3A44Three-phase energy meter with LCD display
Modbus interface, parity 8N1, Imax = 65 A, 2 tariffs
display of active power, voltage and current
according to MID directive
ALE3D5FM10C3A00Three-phase energy meter with LCD display
M-Bus interface, Imax = 65 A, 2 tariffs
display of active power, voltage and current
according to MID directive
ALE3D5FS10C3A00Three-phase energy meter with LCD display
S-Bus interface, Imax = 65 A, 2 tariffs
display of active power, voltage and current
according to MID directive
AWD3B5W10MC3A00Three-phase two-way energy meter with LCD display
S0 pulse output = 10 pulses/kWh
5…1’500 A
display of active power, voltage and current
according to MID directive
AWD3B5WS00C3A00Three-phase two-way energy meter with LCD display
S-Bus interface, 5…1’500 A
display of active power, voltage and current
according to MID directive
AWD3D5W10MC3A00Three-phase energy meter with LCD display
S0 pulse output = 10 pulses/kWh
5…1’500 A, 1 tariff
display of active power, voltage and current
according to MID directive
AWD3D5W10ND3A00Three-phase energy meter with LCD display
S0 pulse output = 1 pulse/kWh
1’000…6’000 A, 1 tariff
display of active power, voltage and current
according to MID directive
AWD3D5WD00C3A00Three-phase energy meter with LCD display
Modbus interface, 5…1’500 A, 1 tariff
display of active power, voltage and current
according to MID directive
AWD3D5WD00C3A44Three-phase energy meter with LCD display
Modbus interface, parity 8N1, 5…1’500 A, 1 tariff
display of active power, voltage and current
according to MID directive
AWD3D5WM00C3A00Three-phase energy meter with LCD display
M-Bus interface, 5…1’500 A, 1 tariff
display of active power, voltage and current
according to MID directive
AWD3D5WS00C3A00Three-phase energy meter with LCD display
S-Bus interface, 5…1’500 A, 1 tariff
display of active power, voltage and current
according to MID directive
BACA-AWiFi access point with
BACnet IP to MS/TP router
with Honeywell Logo
CJ21111-pole socket (47.0 x 47.0 x 20.0 mm) for flush
mounting, connection with screw terminals
CJ25011-pole socket (46.8 x 46.8 x 20.0 mm) for screw
mounting or snap-on mounting on 35 mm DIN rail,
connection with screw terminals
DocumentationThe Saia PCD® technical documentation
is available on our support homepage
(download free of charge at www.sbc-support.com)
EMD1L5F1KA00Single-phase energy meter with LCD display
S0 pulse output = 1’000 pulses/kWh
Imax = 32 A, 1 tariff
IRM-RLC10 terminal covers for
PCD7.LRLx controllers
IRM-RSC10 terminal covers for
PCD7.LRSx controllers
KFD11JVTNDC/DC isolating amplifier, galvanic isolation,
Input ranges 0…10 VDC or 0…20 mA
Output ranges 0…10 VDC or 0…20 mA
KFD12JVTNDC/DC isolating amplifier, galvanic isolation,
Input ranges 0…75 VDC or 0…60 mV
Output ranges 0…10 VDC or 0…20 mA
KFE102NE1NVoltage monitoring relay
230 VAC, 50/60 Hz
memory function, parameterisable,
1 relay (change-over contact)
KFE103NE1NCurrent monitoring relay
230 VAC, 50/60 Hz
memory function, parameterisable,
1 relay (change-over contact)
KFE300NE9NPhase monitoring relay
3 x 400 VAC, 50/60 Hz
analog setting
1 relay (change-over contact)
KFE302NE9NThree-phase voltage monitoring relay (AC)
3 x 400 VAC, 50/60 Hz
memory function, analog setting,
1 relay (change-over contact)
KFT100JE1NTemperature monitoring relay
230 VAC, 50/60 Hz, up to 6 PTC,
automatic reset, 1 relay (make contact)
KFT200KE1NTemperature monitoring relay
230 VAC, 50/60 Hz, up to 6 PTC
memory function, manual or automatic reset
1 relay (change-over contact)
KOL251H7MKVPN00Electronic timer KOL
24…48 VDC and 24…240 VAC
4 time ranges 0.15 s to 10 min
Star-delta timer
KOL311H7MRVPN00Electronic timer KOL
24…48 VDC and 24…240 VAC
6 time ranges 0.05 s to 10 h
Delayed operation
KOL312H7MRVPN00Electronic timer KOL
24…48 VDC and 24…240 VAC
6 time ranges 0.05 s to 10 h
Delayed release
KOL321H7MRVPN00Electronic timer KOL
24…48 VDC and 24…240 VAC
6 time ranges 0.05 s to 10 h
Fleeting-on delay timer
KOL342H7MRVPN00Electronic timer KOL
24…48 VDC and 24…240 VAC
6 time ranges 0.05 s to 10 h
Flasher relay, pulse starting
KOL360H7MRVPN00Electronic timer KOL
24…48 VCC and 24…240 VCA
6 time ranges 0.05 s to 10 h
Multifunction
KOP111J7MWVPN00Electronic timer KOP.J
L24…48 VDC and 24…240 VAC
10 time ranges 0.05 to 60 h
Delayed operation
KOP112J7MWVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
10 time ranges 0.05 to 60 h
Delayed release
KOP119K7MWVAN00Electronic timer KOP.K
24…240 VDC/VAC
4 time ranges 0.15 s to 10 min
Power off delayed release
1 changeover contact
KOP128J7BAVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
Time range 0.05 s to 1 s
Watch dog
KOP128J7CAVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
Time range 0.15 s to 3 s
Watch dog
KOP128J7EAVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
Time range 0.5 s to 10 s
Watch dog
KOP160J7MWVAN00Electronic timer KOP.J
24…240 VDC/VAC
10 time ranges 0.05 s to 60 h
Multifunction
KOP160J7MWVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
10 time ranges 0.05 s to 60 h
Multifunction
KOP170J7MWVPN00Electronic timer KOP.J
24…48 VDC and 24…240 VAC
10 time ranges 0.05 s to 60 h
Asymmetric pulse generator
KOP219K7MWVAN00Electronic timer KOP.K
24…240 VDC/VAC
4 time ranges 0.15 s to 10 min
Power off delayed release
1 changeover contacts
KOP260F0MWVAN00Electronic timer KOP.F
24…230 VDC/VAC
12 time ranges 0.01 s to 10 h
Multifunction
KOP511K7MWVPN00Electronic timer KOP.K
24…48 VDC and 24…240 VAC
10 time ranges 0.05 s to 60 h
Delayed operation
KOP512K7MWVPN00Electronic timer KOP.K
24…48 VDC and 24…240 VAC
10 time ranges 0.05 s to 60 h
Delayed release
KOP560K7MWVAN00Electronic timer KOP.K
24…240 VAC/VDC
10 time ranges 0.05 s to 60 h
Multifunction
KOP560K7MWVPN00Electronic timer KOP.K
24…48 VDC and 24…240 VAC
10 time ranges 0.05 s to 60 h
Multifunction
PCD1.A1000-A20E-Line digital output module
manual override operating level for all outputs
status LED for outputs
supply 24 VDC
10 digital outputs 24 VDC (12…32 VDC/0.5 A)
1 interface RS-485 (S-Bus and Modbus)
PCD1.A2000-A20E-Line digital output module
manual override operating level for all outputs
status LED for outputs
supply 24 VDC
6 relay normally open 230 VAC / 30 VDC, 16 A
(resistive load)
1 interface RS-485 (S-Bus and Modbus)
PCD1.B1000-A20E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
4 digital inputs 24 VDC (source operation)
6 relay normally open 230 VAC / 30 VDC, 4 A
(resistive load)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
1 interface RS-485 (S-Bus and Modbus)
PCD1.B1010-A20E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
24 digital inputs 24 VDC (source operation)
6 relay normally open 230 VAC / 30 VDC, 4 A
(resistive load)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
1 interface RS-485 (S-Bus and Modbus)
PCD1.B1020-A20E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
16 digital inputs 24 VDC (source operation)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
1 interface RS-485 (S-Bus and Modbus)
PCD1.B5000-A20E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
6 digital inputs 115…230 VAC
3 relay normally open 230 VAC / 30 VDC, 6 A
(resistive load)
1 interface RS-485 (S-Bus and Modbus)
PCD1.E1000-A10E-Line digital input module
status LED for inputs
supply 24 VDC
12 digital inputs 24 VDC (source operation)
1 interface RS-485 (S-Bus and Modbus)
PCD1.F2611-C15Programmable E-Line DALI module
for up to 64 DALI ballasts with
integrated DALI-Bus power supply
supply 24 VAC/VDC
4 digital inputs 24 VAC/VDC
4 interfaces: RS-485 (S-Bus), auxiliary RS-485,
USB & NFC (service)
PCD1.G1100-C15Programmable E-Line input/output module
for light and sunblind control
supply 24 VAC/VDC
4 digital inputs 24 VAC/VDC
2 relay changeover 230 VAC / 30 VDC, 8 A,
max. inrush current 15 A,
incl. galvanically isolated current measurement
2 analogue outputs 12 bits, 0…10 V (3 mA max.)
3 interfaces: RS-485 (S-Bus), USB & NFC (service)
PCD1.G2000-A20E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
6 universal digital/analogue inputs
– digital inputs 24 VDC
– analoque inputs 12 bits
0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
2 analogue outputs 10 bits, 0…10 V
2 triac outputs 24 VAC/1A or 230 VAC/1A
1 interface RS-485 (S-Bus and Modbus)
PCD1.G3600-C15Programmable E-Line input/output module
for room automation
supply 24 VAC/VDC
8 digital inputs 24 VAC/VDC
3 relay changeover 230 VAC / 30 VDC, 6 A,
max. inrush current 15 A
1 relay changeover 230 VAC / 30 VDC, 10 A,
max. inrush current 65 A
4 triac outputs 24 VCA/1A or 230 VAC/1 A
4 analogue inputs 12 bits
0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
4 analogue outputs 12 bits, 0…10 V (3 mA max.)
3 interfaces: RS-485 (S-Bus), USB & NFC (service)
PCD1.G3601-C15Programmable E-Line input/output module for
room automation with auxiliary RS-485 interface
supply 24 VAC/VDC
8 digital inputs 24 VAC/VDC
3 relay changeover 230 VAC / 30 VDC, 6 A,
max. inrush current 15 A
1 relay changeover 230 VAC / 30 VDC, 10 A,
max. inrush current 65 A
4 triac outputs 24 VCA/1A or 230 VAC/1 A
4 analogue inputs 12 bits
0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
4 analogue outputs 12 bits, 0…10 V (3 mA max.)
4 interfaces: RS-485 (S-Bus), auxiliary RS-485,
USB & NFC (service)
PCD1.G5000-A20E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
16 digital inputs 24 VDC (source operation)
4 relay normally open 230 VAC / 30 VDC, 4 A
(resistive load)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
8 analogue inputs 12 bits
0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
4 analogue outputs 12 bits, 0…10 V (10 mA max.)
1 interface RS-485 (S-Bus and Modbus)
PCD1.G5010-A20E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
12 digital inputs 24 VDC (source operation)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
12 analogue inputs 12 bits
0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
8 analogue outputs 12 bits, 0…10 V (10 mA max.)
1 interface RS-485 (S-Bus and Modbus)
PCD1.G5020-A20E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
8 digital inputs 24 VDC (source operation)
4 relay changeover 230 VAC / 30 VDC, 4 A
(resistive load)
16 analogue inputs 12 bits
0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
4 analogue outputs 12 bits, 0…10 V (10 mA max.)
1 interface RS-485 (S-Bus and Modbus)
PCD1.K0206-005E-line cover and labelling set consisting
of 5 covers (105 mm) and labelling sheets
for installation in automation control cabinets
PCD1.K0206-025E-line cover and labelling set consisting
of 5 covers (105 mm) with holes for the manual
override operating level and labelling sheets
for installation in automation control cabinets
PCD1.M0160E0Saia PCD® E-Controller with Ethernet TCP/IP,
Energy controller with S-Monitoring function
for electrical cabinet,
web and FTP server, file system,
CPU with 1 MByte user program (RAM),
backup memory, 1 MByte RAM DB/Text,
on-board 128 MByte Flash memory,
USB port for PG5, no I/O module sockets,
on-board I/O :
– 2 interrupt inputs, 1 output (PWM)
– 12 digital I/O (4I/4O/4 configurable)
– 2 analogue inputs (12 bits),
clock (RTC), data protection 1-3 years,
RS-485 (up to 115 kbits/s),
1 port (socket A) for PCD7.F1xxS
PCD1.M2110R1Saia PCD1.Room with Ethernet TCP/IP
for room automation and heavac applications,
web and FTP server, file system,
CPU with 256 KByte user program (RAM),
backup memory,
on-board 8 MByte Flash memory,
USB port for PG5, up to 40 I/O,
1 free I/O module socket,
on-board I/O (with fixed ..W525 on I/O slot 1) :
– 2 interrupt inputs, 1 output (PWM)
– 12 digital I/O (4I/4O/4 configurable)
– 8 analogue I/O (6I/2O),
clock (RTC), data protection 1-3 years,
RS-485 (up to 115 kbits/s),
1 port (socket A) for PCD7.F1xxS,
the Smart RIO Manager function is not supported,
S-Bus and Modbus stations limited to max. 10 units
PCD1.M2120PCD1 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program (RAM),
backup memory,
on-board 8 MByte Flash memory,
USB port for PG5, up to 50 I/O,
2 I/O module sockets,
on-board I/O :
– 2 interrupt inputs, 1 output (PWM)
– 12 digital I/O (4I/4O/4 configurable)
– 2 analogue inputs (12 bits),
clock (RTC), data protection 1-3 years,
RS-485 (up to 115 kbits/s),
1 port (socket A) for PCD7.F1xxS
PCD1.M2160PCD1 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 1 MByte user program (RAM),
backup memory, 1 MByte RAM DB/Text,
on-board 128 MByte Flash memory,
USB port for PG5, up to 50 I/O,
2 I/O module sockets,
on-board I/O :
– 2 interrupt inputs, 1 output (PWM)
– 12 digital I/O (4I/4O/4 configurable)
– 2 analogue inputs (12 bits),
clock (RTC), data protection 1-3 years,
RS-485 (up to 115 kbits/s),
1 port (socket A) for PCD7.F1xxS
PCD1.M2220-C15E-Line processor unit with Ethernet TCP/IP
for electrical switch cabinet,
web and FTP server, file system,
512 KByte user program,
128 KByte RAM DB/Text,
128 MByte Flash memory,
supply 24 VAC/VDC
2 I/O module sockets, 1 M socket,
4 digital inputs, 2 analogue inputs, 1 watchdog
4 interfaces: RS-485 (S-Bus), auxiliary RS-485,
USB & NFC (service)
PCD1.P1001-J30Power Quality Analyser (PQA)
with RS-485 interface
LCD 128 x 64 monochrome 1.9″
LED for I/O and status
supply 110…230 VAC 50/60 Hz
measuring inputs 3PH+N up to 270 VAC
1 digital input 24 VDC, high active
1 digital output 5…24 VDC
2 relay normally open 230 VAC, 6 A (resistive load)
1 analogue input for Pt/Ni 1000 sensor
1 interface RS-485 (S-Bus/Modbus) with
galvanic isolation
PCD1.W5200-A20E-Line analogue output module
manual override operating level for all outputs
status LED for outputs
supply 24 VDC
8 analogue outputs 10 bits, 0…10 V
1 interface RS-485 (S-Bus and Modbus)
PCD1.W5300-C15Programmable E-Line input/output module
for analogue applications
supply 24 VAC/VDC
4 analogue inputs 12 bits
0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC,
0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
4 analogue outputs 12 bits, 0…10 V (4 mA max.)
3 interfaces: RS-485 (S-Bus), USB & NFC (Service)
PCD2.A200Digital output module, 4 relays, 250 VAC/2 A,
‘make’ contact, contact protection
PCD2.A210Digital output module, 4 relays, 250 VAC/2 A,
‘break’ contact, contact protection
PCD2.A220Digital output module, 2 x 3 relays, 250 VAC/2 A
‘make’ contact, without contact protection
PCD2.A250Digital output module, 2 x 4 relays, 48 VAC/2 A
or 50 VDC/2 A,
‘make’ contact, without contact protection
PCD2.A300Digital output module, 6 outputs, transistors,
10…32 VDC/2 A
PCD2.A400Digital output module, 8 outputs, transistors,
5…32 VDC/0.5 A
PCD2.A410Digital output module, 8 outputs, transistors,
5…32 VDC/0.5 A, with galvanic isolation
PCD2.A460Digital output module, 16 outputs, transistors,
10…32 VDC/0.5 A,
ribbon cable connector for PCD2.K2xx
PCD2.A465Digital output module, 16 outputs, transistors,
10…32 VDC/0.5 A, connection with spring terminals
PCD2.B100Digital input/output module with 8 I/O,
2 inputs, 2 outputs and 4 configurable I/O’s
Inputs : 24 VDC, source operation, delay 8 ms
Outputs : breaking capacity 5…32 VDC/0.5 A
PCD2.B160Digital input/output module with 16 I/O,
configurable either as inputs or as outputs
in groups of four (4)
Inputs : 24 VDC, source operation, delay 0.2/8 ms
Outputs : breaking capacity 5…30 VDC/0.5 A
PCD2.C1000Extension housing with 4 I/O module sockets
and 24 VDC power supply for
PCD2.M4560 and PCD2.M5x40
PCD2.C2000Extension housing with 8 I/O module sockets
and 24 VDC power supply for
PCD2.M4560 and PCD2.M5x40
PCD2.E110Digital input module, 8 inputs, 24 VDC,
source and sink operation, 8 ms input delay
PCD2.E111Digital input module, 8 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay
PCD2.E160Digital input module, 16 inputs, 24 VDC,
source and sink operation, 8 ms input delay,
ribbon cable connector for PCD2.K2xx
PCD2.E161Digital input module, 16 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay,
ribbon cable connector for PCD2.K2xx
PCD2.E165Digital input module, 16 inputs, 24 VDC,
source and sink operation, 8 ms input delay,
connection with spring terminals to max 0.5 mm2
PCD2.E166Digital input module, 16 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay,
connection with spring terminals to max 0.5 mm2
PCD2.E500Digital input module, 6 inputs, 110…240 VAC,
with galvanic isolation, source operation
PCD2.E610Digital input module, 8 inputs, 24 VDC,
with galvanic isolation, source and sink operation,
8 ms delay
PCD2.E611Digital input module, 8 inputs, 24 VDC,
with galvanic isolation, source and sink operation,
0.2 ms delay
PCD2.E613Digital input module, 8 inputs, 48 VDC,
with galvanic isolation, source and sink operation,
9 ms delay
PCD2.F2100Serial interface module with 1x RS-422 / RS-485
and 1 socket for PCD7.F1xxS module
PCD2.F2150BACnet MS/TP serial interface module
with 1x RS-422 / RS-485 and
1 socket for PCD7.F1xxS module
PCD2.F2210Serial interface module with 1x RS-232
and 1 socket for PCD7.F1xxS module
PCD2.F2400LonWorks® interface module (Lon FTT10)
for up to 254 network variables and
1 socket for PCD7.F1xxS module
PCD2.F2610DALI master interface module
for up to 64 DALI ballasts,
with integrated DALI-Bus power supply
PCD2.F2700M-Bus master interface module
for up to 240 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
PCD2.F2710M-Bus master interface module
for up to 20 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
PCD2.F2720M-Bus master interface module
for up to 60 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
PCD2.F2810Belimo MP-Bus interface module
for up to 8 drives and
1 socket for PCD7.F1xxS module
PCD2.G200Multifunction module (2 sockets side-by-side) with:
4 digital inputs, 24 VDC, 8 ms delay
4 digital outputs, 10…32 VDC/0.5 A,
8 analogue inputs, 12 bits, for
– 2x 0…10 V,
– 2x Pt/Ni 1000,
– 4x selectable via jumper as
0…10 V, 0…20 mA or Pt/Ni 1000
8 analogue outputs, 10 bits, 0…10 V
PCD2.H112Intelligent fast counting module, 150 kHz,
2 counting channels for incremental sensor inputs
PCD2.H114Intelligent fast counting module, 150 kHz,
4 counting channels for incremental sensor inputs
PCD2.H150Absolute encoder module with SSI interface
and 4 outputs 24 VDC/0.5 A
PCD2.H222Pulse output module for 2 independent
stepper motor axes
PCD2.H310Positioning module for 1 servomotor axis,
encoder input 24 VDC/100 kHz,
setpoint output ±10 V (12 bits)
PCD2.H311Positioning module for 1 servomotor axis,
encoder input 5 VDC/100 kHz,
setpoint output ±10 V (12 bits)
PCD2.K010I/O bus connector for PCD2.M4560 to
PCD2.Cx000 or PCD2.Cx000 to PCD2.Cx000
PCD2.K106Extension cable for PCD2.M5x40 to
PCD2.C1000/..C2000 or PCD3.Cxx0
(length 0.9 m – from version C)
PCD2.K221Plug-in system cable for digital modules
with 16 I/Os.
Sheathed, round cable, length 1.5 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: strand ends free, colour-coded
PCD2.K223Plug-in system cable for digital modules
with 16 I/Os.
Sheathed, round cable, length 3.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: strand ends free, colour-coded
PCD2.K231Plug-in system cable for terminal adapters
PCD2.K520/..K521/..K525.
Sheathed, half-round cable, length 1.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: 34-pole ribbon cable connector
PCD2.K232Plug-in system cable for terminal adapters
PCD2.K520/..K521/..K525.
Sheathed, half-round cable, length 2.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: 34-pole ribbon cable connector
PCD2.K241Plug-in system cable for 2 terminal adapters
PCD2.K51x or relay interface PCD2.K55x.
Sheathed, half-round cable, length 1.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: two 16-pole ribbon cable connectors
PCD2.K241Plug-in system cable for 2 terminal adapters
PCD2.K51x or relay interface PCD2.K55x.
Sheathed, half-round cable, length 1.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: two 16-pole ribbon cable connectors
PCD2.K242Plug-in system cable for 2 terminal adapters
PCD2.K51x or relay interface PCD2.K55x.
Sheathed, half-round cable, length 2.0 m (type D);
PCD side: 34-pole ribbon cable connector
Process side: two 16-pole ribbon cable connectors
PCD2.K271Plug-in system cable for analogue I/O modules
and ..H modules.
Sheathed, screened, round cable, length 1.5 m;
PCD side: 10-pole, plug-in screw terminal block
Process side: strand ends free, numbered
PCD2.K510Ribbon / screw terminal adapter for
8 inputs or 8 outputs, without LEDs;
PCD side: 16-pole ribbon connector
Process side: 2 x 6 screw terminals
PCD2.K511Ribbon / screw terminal adapter for
8 inputs or 8 outputs, with LEDs (source operation);
PCD side: 16-pole ribbon connector
Process side: 2 x 6 screw terminals
PCD2.K520Ribbon / screw terminal adapter for
16 inputs or 16 outputs, without LEDs;
PCD side: 34-pole ribbon connector
Process side: 2 x 10 screw terminals
PCD2.K521Ribbon / screw terminal adapter for
16 inputs or 16 outputs, with LEDs (source operation);
PCD side: 34-pole ribbon connector
Process side: 2 x 10 screw terminals
PCD2.K525Ribbon / screw terminal adapter for
16 inputs or 16 outputs, with LEDs (source operation);
PCD side: 34-pole ribbon connector
Process side: 3 x 16 screw terminals
PCD2.K551Relay interface module for
8 transistor outputs, with LEDs;
PCD side: screw terminals or
16-pole ribbon connector
Process side: 24 screw terminals
PCD2.K552Relay interface module for
8 transistor outputs, with LEDs,
manual control mode (switch on-off-auto) and
1 output feedback signal of manual mode;
PCD side: screw terminals or
16-pole ribbon connector
Process side: 24 screw terminals
PCD2.M4160PCD2 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
512 kByte user program,
128 kByte RAM DB/Text,
8 MByte Flash memory,
4 I/O module sockets (2 for PCD2.F2xxx),
clock (RTC),
interfaces: Ethernet, USB, RS-485 (187.5 Kbits/s),
1 slot A for PCD7.F1xxS
PCD2.M4560PCD2 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
2 MByte user program,
1 MByte RAM DB/Text,
128 MByte Flash memory,
4 I/O module sockets, expandable up to 1024 I/O,
clock (RTC),
interfaces: Ethernet, USB, RS-485 (187.5 kbits/s),
RS-485 (1.5 Mbits/s),
1 slot A for PCD7.F1xxS,
1 slot C for Profibus or CAN
PCD2.M5540PCD2 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 1 MByte user program (RAM),
1x Ethernet TCP/IP (2x RJ45 switch),
USB port for PG5, up to 1024 I/O,
expandable with PCD2.Cxx0 or PCD3.Cxx0,
8 I/O module sockets,
on-board I/O: 6 interrupt inputs, 2 outputs (PWM),
clock (RTC), data protection 1-3 years,
RS-232, RS-485 (115 kbits/s), Profi-S-Net/MPI,
3 sockets A1/A2/C for communication modules
PCD2.R6000Basic module for SD Flash memory card,
for PCD2.M5xxx, plug-in onto I/O slot 0…3
(Saia PCD® SD card not included)
PCD2.W200Analogue input module, 8 channels, 10 bits,
0…10 V
PCD2.W210Analogue input module, 8 channels, 10 bits,
0…20 mA
PCD2.W220Analogue input module, 8 channels, 10 bits,
Pt/Ni 1000
PCD2.W220Z02Analogue input module, 8 channels, 10 bits,
NTC10 temperature sensors
PCD2.W220Z12Analogue input module, 8 channels, 10 bits,
4 inputs 0…10 V and 4 inputs Pt/Ni 1000
PCD2.W300Analogue input module, 8 channels, 12 bits,
0…10 V
PCD2.W305Analogue input module with galvanic isolation,
7 channels, 12 bits, 0…10 V
PCD2.W310Analogue input module, 8 channels, 12 bits,
0…20 mA
PCD2.W315Analogue input module with galvanic isolation,
7 channels, 12 bits, 0(4)…20 mA
PCD2.W325Analogue input module with galvanic isolation,
7 channels, 12 bits, ±10 V
PCD2.W340Universal analogue input module, 8 channels,
12 bits, 0…10 V, 0…2.5 V, 0…20 mA, Pt/Ni 1000
PCD2.W350Analogue input module, 8 channels, 12 bits,
Pt/Ni 100
PCD2.W360Analogue input module, 8 channels, 12 bits,
Pt 1000 (-50…+150°C, 0.1°C)
PCD2.W380Universal analogue input module, 8 channels,
13 bits (12 bits+sign), selectable by software,
0…10 V, ±10 V, 0…20 mA, ±20 mA, Pt/Ni 1000,
0…2500 Ohm, 0…300 kOhm (for NTC sensors)
PCD2.W400Analogue output module, 4 channels, 8 bits,
0…10 V
PCD2.W410Analogue output module, 4 channels, 8 bits,
0…10 V / 0…20 mA / 4…20 mA,
jumper selectable
PCD2.W525Analogue combined input/output module
with galvanic isolation, 6 channels :
4 inputs,   14 bits, 0…10 V, 0(4)…20 mA,
Pt 1000, Pt 500 or Ni 1000
(selectable by DIP switch) and
2 outputs, 12 bits, 0…10 V or 0(4)…20 mA
(selectable by software (FBox, FB)
PCD2.W600Analogue output module, 4 channels, 12 bits,
0…10 V
PCD2.W605Analogue output module with galvanic isolation,
6 channels, 10 bits, 0…10 V
PCD2.W610Analogue output module, 4 channels, 12 bits,
0..10 V / ± 10V / 0…20 mA
PCD2.W615Analogue output module with galvanic isolation,
4 channels, 10 bits, 0(4)…20 mA
PCD2.W625Analogue output module with galvanic isolation,
6 channels, 10 bits, ±10 V
PCD2.W720Weighing module with 2 systems for up
to 6 weighing cells, resolution 18 bits
PCD2.W745Universal temperature measurement module for
up to 4 measuring inputs, resolution 16 bits,
for TC Type J & K and 4 wires Pt/Ni 100/1000
PCD3.A200Digital output module, 4 relays, 250 VAC/2 A,
‘make’ contact, contact protection
(connector type A included)
PCD3.A210Digital output module, 4 relays, 250 VAC/2 A,
‘break’ contact, contact protection
(connector type A included)
PCD3.A220Digital output module, 2 x 3 relays, 250 VAC/2 A
‘make’ contact, without contact protection
(connector type A included)
PCD3.A251Digital output module, 8 relays, 48 VAC/2 A
or 50 VDC/2 A with 6 change-over contacts and
2 make-contacts (connector type C included)
PCD3.A300Digital output module, 6 outputs, transistors,
10…32 VDC/2 A (connector type A included)
PCD3.A400Digital output module, 8 outputs, transistors,
5…32 VDC/0.5 A (connector type A included)
PCD3.A410Digital output module, 8 outputs, transistors,
5…32 VDC/0.5 A, with galvanic isolation
(connector type A included)
PCD3.A460Digital output module, 16 outputs, transistors,
10…32 VDC/0.5 A,
ribbon cable connector for PCD2.K2xx
PCD3.A465Digital output module, 16 outputs, transistors,
10…32 VDC/0.5 A (connector type C included)
PCD3.A810Digital local control module with 4 relays outputs
– 2 ‘changeover’ contacts
– 2 ‘make’ contacts
Connection with PCD3.K810
(connector type F included)
PCD3.A860Light and shade control module with
– 2 relays outputs 250 VAC/12 A
– 2 digital inputs 24 VDC
Connection with PCD3.K86x
(connector type G and H included)
PCD3.B100Digital input/output module with 8 I/O,
2 inputs, 2 outputs and 4 configurable I/O’s
Inputs : 24 VDC, source operation, delay 8 ms
Outputs : breaking capacity 5…32 VDC/0.5 A
(connector type A included)
PCD3.B160Digital input/output module with 16 I/O,
configurable either as inputs or as outputs
in groups of four (4)
Inputs : 24 VDC, source operation, delay 0.2/8 ms
Outputs : breaking capacity 5…30 VDC/0.5 A
(2 connectors type K included)
PCD3.C100Extension module holder for 4 I/O modules
PCD3.C110Extension module holder for 2 I/O modules
PCD3.C110Z09Extension module holder for 2 I/O modules
for compact controllers Saia PCD3
PCD3.C200Extension module holder for 4 I/O modules with
terminal connectors for external 24 VDC power supply
PCD3.C200Z09Extension module holder for 4 I/O modules with
terminal connectors for external 24 VDC power
supply for compact controllers Saia PCD3
PCD3.E009Empty module housing
for unused PCD3 I/O slots
PCD3.E110Digital input module, 8 inputs, 24 VDC,
source and sink operation, 8 ms input delay.
(connector type A included)
PCD3.E111Digital input module, 8 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay
(connector type A included)
PCD3.E160Digital input module, 16 inputs, 24 VDC,
source and sink operation, 8 ms input delay,
ribbon cable connector for PCD2.K2xx
PCD3.E161Digital input module, 16 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay,
ribbon cable connector for PCD2.K2xx
PCD3.E165Digital input module, 16 inputs, 24 VDC,
source and sink operation, 8 ms input delay,
(connector type C included)
PCD3.E166Digital input module, 16 inputs, 24 VDC,
source and sink operation, 0.2 ms input delay,
(connector type C included)
PCD3.E500Digital input module, 6 inputs, 110…240 VAC,
with galvanic isolation, source operation,
20 ms input delay (connector type A included)
PCD3.E610Digital input module, 8 inputs, 24 VDC,
with galvanic isolation, source and sink operation,
10 ms input delay (connector type A included)
PCD3.E613Digital input module, 8 inputs, 48 VDC,
with galvanic isolation, source and sink operation,
9 ms delay (connector type A included)
PCD3.F110Serial interface module RS-422 / RS-485
(connector type A included)
PCD3.F121Serial interface module RS-232 up to 115.2 kBit/s,
suitable for modem connection
(connector type A included)
PCD3.F150Serial interface module RS-485 with
galvanic isolation (connector type A included)
PCD3.F180Belimo MP-Bus interface module,
max. 8 actuators and sensors connectable
(connector type A included)
PCD3.F210Serial interface module
with 1x RS-422 / RS-485 and
1 socket for PCD7.F1xxS module
(2 connectors type K included)
PCD3.F215BACnet MS/TP serial interface module
with 1x RS-422 / RS-485 and
1 socket for PCD7.F1xxS module
(2 connectors type K included)
PCD3.F221Serial interface module with 1x RS-232
and 1 socket for PCD7.F1xxS module
(2 connectors type K included)
PCD3.F240LonWorks® interface module (Lon FTT10)
for up to 254 network variables and
1 socket for PCD7.F1xxS module
(connector type A included)
PCD3.F261DALI master interface module
for up to 64 DALI ballasts,
with integrated DALI-Bus power supply
(connector type A included)
PCD3.F270M-Bus master interface module
for up to 240 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
(connector type A included)
PCD3.F271M-Bus master interface module
for up to 20 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
(connector type A included)
PCD3.F272M-Bus master interface module
for up to 60 M-Bus slave addresses
freely distributable on 2 M-Bus interfaces
(connector type A included)
PCD3.F281Belimo MP-Bus interface module
for up to 8 drives and
1 socket for PCD7.F1xxS module
(2 connectors type K included)
PCD3.H112Intelligent fast counting module, 150 kHz,
2 counting channels for incremental sensor inputs
(2 connectors type K included)
PCD3.H114Intelligent fast counting module, 150 kHz,
4 counting channels for incremental sensor inputs
(2 connectors type K included)
PCD3.H150Absolute encoder module with SSI interface
and 4 outputs 24 VDC/0.5 A
(connector type A included)
PCD3.H222Pulse output module for 2 independent
stepper motor axes (2 connectors type K included)
PCD3.H310Positioning module for 1 servomotor axis,
encoder input 24 VDC/100 kHz,
setpoint output ±10 V (12 bits)
(connector type A included)
PCD3.H311Positioning module for 1 servomotor axis,
encoder input 5 VDC/100 kHz,
setpoint output ±10 V (12 bits)
(connector type A included)
PCD3.K010Connection plug PCD3.M/T/C to PCD3.Cxx0
PCD3.K106Extension cable for PCD2.M4560 to PCD2.Cx000,
PCD3.M/T/C to PCD3.Cxx0 or PCD2.C1000/..C2000 to PCD2.C1000/..C2000
(length 0.7 m)
PCD3.K116Extension cable for PCD2.M4560 to PCD2.Cx000,
PCD3.M/T/C to PCD3.Cxx0 or
PCD2.C1000/..C2000 to PCD2.C1000/..C2000
(length 1.2 m)
PCD3.M2130V6PCD3 Compact with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program (RAM),
backup with on-board Flash memory,
1 MByte on-board Flash memory for file system,
USB port for PG5, 2 interrupt inputs, RS-485,
32 digital I/O (20I/12O), 6 analogue I/O (4I/2O),
1 port (socket A) for PCD7.F1xxS,
data protection 1-3 years
PCD3.M2330A4T5PCD3 WAC with GSM/GPRS modem & Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program (RAM),
backup with on-board Flash memory,
1 MByte on-board Flash memory for file system,
slot for SD Flash memory card,
USB port for PG5, 2 interrupt inputs, RS-485,
10 digital I/O (8I/2O), 4 analogue I/O (4I/0O),
1 port (socket A) for PCD7.F1xxS,
data protection 1-3 years
PCD3.M3120PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 128 KByte user program,
backup with on-board Flash memory, clock (RTC),
USB port for PG5, up to 64 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net or S-Bus
PCD3.M3160PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program,
128 MByte user Flash memory with file system,
clock (RTC),
USB port for PG5, up to 64 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net or S-Bus
PCD3.M3330PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program,
backup with on-board Flash memory, clock (RTC),
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net or S-Bus
PCD3.M3360PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 512 KByte user program,
128 MByte user Flash memory with file system,
clock (RTC),
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net or S-Bus
PCD3.M5340PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 1 MByte user program,
backup option with PCD7.R5xx/R610 Flash card,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus
PCD3.M5360PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 2 MByte user program,
128 MByte user Flash memory with file system, clock (RTC),
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus,
data protection 1-3 years
PCD3.M5540PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 1 MByte user program,
backup option with PCD7.R5xx/R610 Flash card,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus
PCD3.M5560PCD3 processor unit with Ethernet TCP/IP,
web and FTP server, file system,
CPU with 2 MByte user program,
1 MByte SRam extension memory,
128 MByte user Flash memory with file system,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupts,
RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus
PCD3.M6560PCD3 processor unit with Profibus DP Master and
Ethernet TCP/IP, web and FTP server, file system,
CPU with 2 MByte user program,
1 MByte SRam extension memory,
128 MByte user Flash memory with file system,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-232, RS-485 for Profi-S-Net/MPI/S-Bus
PCD3.M6860PCD3 processor unit with 2 Ethernet TCP/IP,
web and FTP server, file system,
CPU with 2 MByte user program,
1 MByte SRam extension memory,
128 MByte user Flash memory with file system,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net/MPI/S-Bus
PCD3.M6880PCD3 Standby processor unit with 2 Ethernet TCP/IP
and Co-processor for Standby operation,
web and FTP server, file system,
CPU with 2 MByte user program,
1 MByte SRam extension memory,
128 MByte user Flash memory with file system,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net/MPI/S-Bus
PCD3.R010Battery module for PCD3.M3xxx,
plug-in onto I/O Slot #3
PCD3.R562Flash memory module for BACnet® firmware
with 128 MByte file system
(for user program backup, web pages, ..),
for PCD3.Mxxxx with Ethernet TCP/IP
(plug-in onto I/O slot 0…3)
PCD3.R600Basic module for SD Flash memory card,
plug-in onto I/O slot 0…3
(Saia PCD® SD card not included)
PCD3.S100Input/Output Simulator for PCD3.M/.T/.C
(for ex. for test assembly or workshop models)
PCD3.T665Smart-RIO, Ether-S-IO data exchange,
programmable, 32 KByte program memory,
up to 256 I/O, 2 Interrupts, web server
PCD3.T666Smart-RIO, Ether-S-IO data exchange,
programmable, 128 KByte program memory,
up to 256 I/O, 2 Interrupts, web server
and on-board RS-485 interface
PCD3.T668Smart-RIO for Standby processor unit,
Ether-S-IO data exchange, programmable,
128 KByte program memory,
up to 256 I/O, 2 Interrupts, web server
and on-board RS-485 interface
PCD3.W200Analogue input module, 8 channels, 10 bits,
0…10 V (connector type A included)
PCD3.W210Analogue input module, 8 channels, 10 bits,
0…20 mA (connector type A included)
PCD3.W220Analogue input module, 8 channels, 10 bits,
Pt/Ni 1000 (connector type A included)
PCD3.W220Z03Analogue input module, 8 channels, 10 bits,
NTC10 temperature sensors
(connector type A included)
PCD3.W220Z12Analogue input module, 8 channels, 10 bits,
4 inputs 0…10 V and 4 inputs Pt/Ni 1000
(connector type A included)
PCD3.W300Analogue input module, 8 channels, 12 bits,
0…10 V (connector type A included)
PCD3.W305Analogue input module with galvanic isolation,
7 channels, 12 bits, 0…10 V
(connector type E included)
PCD3.W310Analogue input module, 8 channels, 12 bits,
0…20 mA (connector type A included)
PCD3.W315Analogue input module with galvanic isolation,
7 channels, 12 bits, 0(4)…20 mA
(connector type E included)
PCD3.W325Analogue input module with galvanic isolation,
7 channels, 12 bits, ±10 V
(connector type E included)
PCD3.W340Universal analogue input module, 8 channels,
12 bits, 0…10 V, 0…2.5 V, 0…20 mA, Pt/Ni 1000
(connector type A included)
PCD3.W350Analogue input module, 8 channels, 12 bits,
Pt/Ni 100 (connector type A included)
PCD3.W360Analogue input module, 8 channels, 12 bits,
Pt 1000 (-50…+150°C, 0.1°C)
(connector type A included)
PCD3.W380Universal analogue input module, 8 channels,
13 bits (12 bits+sign), selectable by software,
0…10 V, ±10 V, 0…20 mA, ±20 mA, Pt/Ni 1000,
0…2500 Ohm, 0…300 kOhm (for NTC sensors)
(2 connectors type K included)
PCD3.W400Analogue output module, 4 channels, 8 bits,
0…10 V (connector type A included)
PCD3.W410Analogue output module, 4 channels, 8 bits,
0…10 V / 0…20 mA / 4…20 mA,
jumper selectable (connector type A included)
PCD3.W525Analogue combined input/output module
with galvanic isolation, 6 channels :
4 inputs,   14 bits, 0…10 V, 0(4)…20 mA,
Pt 1000, Pt 500 or Ni 1000
(selectable by DIP switch) and
2 outputs, 12 bits, 0…10 V or 0(4)…20 mA
(selectable by software (FBox, FB)
(connector type E included)
PCD3.W600Analogue output module, 4 channels, 12 bits,
0…10 V (connector type A included)
PCD3.W605Analogue output module with galvanic isolation,
6 channels, 10 bits, 0…10 V
(connector type E included)
PCD3.W610Analogue output module, 4 channels, 12 bits,
0…10 V / ±10 V / 0…20 mA (connector type A included)
PCD3.W615Analogue output module with galvanic isolation,
4 channels, 10 bits, 0(4)…20 mA
(connector type E included)
PCD3.W625Analogue output module with galvanic isolation,
6 channels, 10 bits, ±10 V
(connector type E included)
PCD3.W720Weighing module with 2 systems for up
to 6 weighing cells, resolution 18 bits
(connector type E included)
PCD3.W745Universal temperature measurement module for
up to 4 measuring inputs, resolution 16 bits,
for TC Type J & K and 4 wires Pt/Ni 100/1000
(with soldered I/O spring terminal block)
PCD3.W800Analogue local control module with 4 channels
– 3 outputs 0..10 V with local control
– 1 output 0..10 V without local control
Connection with PCD3.K800
(connector type J included)
PCD7.D170Small terminal with 5 keys for front panel flush
mounting with display of 4 x 16 characters, RS 232
PCD7.D230Terminal for front panel flush mounting (IP 54),
single-knob control, graphic LCD display
of 8 x 20 characters, RS-232 / RS-422 / RS-485
PCD7.D230Z11Terminal for front panel flush mounting PCD7.D230
without SBC logo
PCD7.D231Terminal for front panel flush mounting (IP 65),
with 10 function keys, graphic LCD display
of 8 x 20 characters, RS-232 / RS-422 / RS-485
PCD7.D231Z11Terminal for front panel flush mounting PCD7.D231
without SBC logo
PCD7.D232Terminal for front panel flush mounting (IP 65),
with 25 function keys, 8 LED; graphic LCD display
of 8 x 20 characters, RS-232 / RS-422 / RS-485
PCD7.D232Z11Terminal for front panel flush mounting PCD7.D232
without SBC logo
PCD7.D410-IWSKit for in-wall mounting of the Micro-Browser
Web panels 10.4″
PCD7.D410-OWSKit for on-wall mounting of the Micro-Browser
Web panels 10.4″
PCD7.D410VT5FProgrammable Web panel with
embedded Micro-Browser,
Base line 10.4″ TFT VGA, 640 x 480 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
programmable with Saia PG5® tool,
128 MByte on-board file system,
web and FTP server,
2x Ethernet TCP/IP (switch), RS-485 and socket
for PCD7.F1xxS, for front panel flush mounting
PCD7.D410VT5Z11Programmable Web panel PCD7.D410VT5F
with embedded Micro-Browser,
with neutral laminated front overlay
(without SBC logo and code)
PCD7.D410VTCFWeb panel with embedded Micro-Browser,
Base line 10.4″ TFT VGA, 640 x 480 pixels,
65’536 colours with touch screen,
transmissive CCFL backlight,
4 MByte on-board file system, FTP server,
Ethernet TCP/IP, PS/2 and printer interfaces,
for front panel flush mounting.
PCD7.D410VTCZ11Web panel PCD7.D410VTCF with embedded
Micro-Browser, with neutral laminated front overlay
(without SBC logo and code)
PCD7.D412DT5FProgrammable Web panel with
embedded Micro-Browser,
Base line 12.1″ TFT SVGA, 800 x 600 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
programmable with Saia PG5® tool,
128 MByte on-board file system,
web and FTP server,
2x Ethernet TCP/IP (switch), RS-485 and socket
for PCD7.F1xxS, for front panel flush mounting
PCD7.D412DT5Z11Programmable Web panel PCD7.D412DT5F
with embedded Micro-Browser,
with neutral laminated front overlay
(without SBC logo and code)
PCD7.D412DTPFWeb panel with embedded Micro-Browser,
Base line 12.1″ TFT SVGA, 800 x 600 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
128 MByte on-board file system, FTP server,
2x Ethernet TCP/IP (switch),
for front panel flush mounting.
PCD7.D412DTPZ11Web panel PCD7.D412DTPF with embedded
Micro-Browser, with neutral laminated front overlay
(without SBC logo and code)
PCD7.D412-IWSKit for in-wall mounting of the Micro-Browser
Web panels 12.1″
PCD7.D412-OWSKit for on-wall mounting of the Micro-Browser
Web panels 12.1″
PCD7.D443WT5RProgrammable Room Web panel with
embedded Micro-Browser, black housing
Base line 4.3″ TFT WQVGA, 480 x 272 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
programmable with Saia PG5® tool,
128 MByte on-board file system,
web and FTP server, temperature sensor,
Ethernet TCP/IP, RS-485, for in-wall mounting
PCD7.D443WT5RWProgrammable Room Web panel with
embedded Micro-Browser, black housing
Base line 4.3″ TFT WQVGA, 480 x 272 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
programmable with Saia PG5® tool,
128 MByte on-board file system,
web and FTP server, temperature sensor,
Ethernet TCP/IP, RS-485, for in-wall mounting
PCD7.D443WTPRRoom Web panel with embedded Micro-Browser,
black housing,
Base line 4.3″ TFT WQVGA, 480 x 272 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
4MByte on-board file system, FTP server,
temperature sensor, Ethernet TCP/IP,
for in-wall mounting
PCD7.D443WTPRWRoom Web panel with embedded Micro-Browser,
white housing,
Base line 4.3″ TFT WQVGA, 480 x 272 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
4MByte on-board file system, FTP server,
temperature sensor, Ethernet TCP/IP,
for in-wall mounting
PCD7.D450WTPFWeb panel with embedded Micro-Browser,
Base line 5.0″ TFT WVGA, 800 x 480 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
128 MByte on-board file system, FTP server,
Ethernet TCP/IP, for front panel flush mounting
PCD7.D450WTPZ11Web panel PCD7.D450WTPF with embedded
Micro-Browser, with neutral laminated front overlay
(without SBC logo and code)
PCD7.D457-IWS2Kit for in-wall mounting of the Micro-Browser
Web panels 5.7″ and 7″
PCD7.D457-OWSKit for on-wall mounting of the Micro-Browser
Web panels 5.7″ and 7″
PCD7.D457-OWS1Kit for on-wall mounting of the Micro-Browser
Web panels 5.7″ and 7″ with space for power supply
PCD7.D457-OWS2Kit for on-wall mounting of the Micro-Browser
Web panels 5.7″ and 7″
PCD7.D457VT5FProgrammable Web panel with
embedded Micro-Browser,
Base line 5.7″ TFT VGA, 640 x 480 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
programmable with Saia PG5® tool,
128 MByte on-board file system,
web and FTP server,
2x Ethernet TCP/IP (switch), RS-485 and socket
for PCD7.F1xxS, for front panel flush mounting
PCD7.D457VT5Z11Programmable Web panel PCD7.D457VT5F
with embedded Micro-Browser,
with neutral laminated front overlay
(without SBC logo and code)
PCD7.D457VTCFWeb panel with embedded Micro-Browser,
Base line 5.7″ TFT VGA, 640 x 480 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
4 MByte on-board file system, FTP server,
Ethernet TCP/IP, for front panel flush mounting
PCD7.D457VTCZ11Web panel PCD7.D457VTCF with embedded
Micro-Browser, with neutral laminated front overlay
(without SBC logo and code)
PCD7.D457VTCZ34Web panel PCD7.D457VTCF with embedded
Micro-Browser, without front overlay
PCD7.D457VTCZ35Web panel PCD7.D457VTCF with embedded
Micro-Browser, with black and sparkling front overlay
PCD7.D470WTPFWeb panel with embedded Micro-Browser,
Base line 7.0″ TFT WVGA, 800 x 480 pixels,
65’536 colours with touch screen,
transmissive LED backlight,
128 MByte on-board file system, FTP server,
Ethernet TCP/IP, for front panel flush mounting
PCD7.D470WTPZ11Web panel PCD7.D470WTPF with embedded
Micro-Browser, with neutral laminated front overlay
(without SBC logo and code)
PCD7.D5120WTA010Web panel equipped with Windows CE :
– 12″ TFT colour display and resistive touch
– WXGA 1280 x 800 pixels
– CPU Atom E640 1.0 GHz
– 1 GByte RAM, 1x SD card slot
– 1x Ethernet 10/100/100 Mbits/s
– 1x Ethernet 10/100 Mbits/s
– 3x USB 2.0 host interface
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.D5150WTA010Web panel equipped with Windows CE :
– 15″ TFT colour display and resistive touch
– WXGA 1280 x 800 pixels
– CPU Atom E640 1.0 GHz
– 1 GByte RAM, 1x SD card slot
– 1x Ethernet 10/100/100 Mbits/s
– 1x Ethernet 10/100 Mbits/s
– 3x USB 2.0 host interface
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.D6120WTA010Web panel equipped with WES7 :
– 12″ TFT colour display and resistive touch
– WXGA 1280 x 800 pixels
– CPU Atom E680 1.6 GHz
– 2 GByte RAM, 1x SD card slot
– 1x Ethernet 10/100/100 Mbits/s
– 1x Ethernet 10/100 Mbits/s
– 3x USB 2.0 host interface
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.D6150WTA010Web panel equipped with WES7 :
– 15″ TFT colour display and resistive touch
– WXGA 1280 x 800 pixels
– CPU Atom E680 1.6 GHz
– 2 GByte RAM, 1x SD card slot
– 1x Ethernet 10/100/100 Mbits/s
– 1x Ethernet 10/100 Mbits/s
– 3x USB 2.0 host interface
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.D6150WTC010Panel PC equipped with WES7 :
– 15″ TFT colour display and resistive touch
– WXGA 1280 x 800 pixels
– CPU Celeron 2x 1.6 GHz
– 2 GByte RAM, iHDD
– 2x Ethernet 10/100/100 Mbits/s
– 4x USB 2.0 host interface
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.D6210WTI010Panel PC equipped with WES7 :
– 21″ TFT colour display and resistive touch
– WUXGA 1920 x 1080 pixels
– CPU I7 4x 2.1 GHz
– 4 GByte RAM, iHDD
– 2x Ethernet 10/100/100 Mbits/s
– 4x USB 2.0 host interface,
– 2x D-SUB RS-232 + RS-485 combined
– 24 VDC power supply
PCD7.F110SSerial interface module RS-422 / RS-485
.
PCD7.F121SSerial interface module RS-232 up to 115 kbit/s
suitable for modem connection
PCD7.F150SSerial interface module RS-485
with galvanic isolation
PCD7.F180SBelimo MP-Bus interface module,
max. 8 actuators and sensors connectable
PCD7.F7500Profibus DP master interface, 12 MBaud,
for PCD2.M5xxx onto socket C
PCD7.H104DPulse counter for collecting, converting
and transmitting S0 pulses via Modbus,
with 4 S0 pulse inputs,
powered by 230 VAC, 50/60 Hz
PCD7.H104DZ44Pulse counter for collecting, converting
and transmitting S0 pulses via Modbus,
parity 8N1, with 4 S0 pulse inputs,
powered by 230 VAC, 50/60 Hz
PCD7.H104SEPulse counter for collecting, converting
and transmitting S0 pulses via S-Bus,
with 4 S0 pulse inputs,
powered by 230 VAC, 50/60 Hz
PCD7.K412Shielded interface connection cable RS-232
between PGU connector and terminal;
D-type 9-pole at both ends, length 2.5 m
PCD7.K413Shielded interface connection cable RS-232 with
RTS/CTS between PGU connector and terminal;
D-type 9-pole at both ends, length 2.5 m
PCD7.K423Shielded interface connection cable RS-232
with RTS/CTS between RS-232 interface of PCD
(wire ends free) and terminal (D-type 9-pole);
length 2.5 m
PCD7.K456Shielded interface connection cable RS-485
between RS-485 interface of PCD (wire ends free)
and terminal (D-type 9-pole); length 5.0 m
PCD7.K840GSM/UMTS (850/900/1800/1900/2100 MHz) antenna
with magnetic foot and SMA connector
PCD7.L100Digital input module, 4 inputs 24 VDC/VAC,
with local override functionality
PCD7.L110Digital input module, 4 inputs 24 VDC/VAC,
without local override functionality
PCD7.L120Digital input/output module, 4 inputs
24 VDC/VAC and 2 relay outputs 250 VAC,
with local override and integrated
light & sunblind functionality
PCD7.L121Digital input/output module, 4 inputs
24 VDC/VAC and 2 relay outputs 250 VAC,
with local override and integrated
light & sunblind functionality (protection class IP 65)
PCD7.L130Digital input module, 10 inputs 24 VDC/VAC
PCD7.L200Digital output module, 4 relays 250 VAC/6 A,
with local override functionality
PCD7.L210Digital output module, 4 triac 24…250 VAC/0.8 A,
with local override functionality
PCD7.L252Changeover switch with local override
functionality Auto/On/Off :
1 changeover switch max. 250 VDC/VAC/8 A,
local override, auto acknowledge,
LED indicator,
2 added terminals for jumpers,
11.2 mm overall width, spring terminals
PCD7.L260Coupler module for two-stage motor control :
mutually latched relay 250 VDC/VAC/4 A,
local override, auto acknowledge,
LED indicator,
22.5 mm overall width, screw terminals
PCD7.L290Labelling plate for PCD7.L252 module
Price for 10 pieces
PCD7.L291Jumper for connection of the supply voltage
of up to 10 modules PCD7.L252 and PCD7.L452
PCD7.L320Analogue input module with 8 universally
configurable channels for 0 … 10 VDC or
various passive and active temperature sensors
such as Pt 1000, Ni 1000, NTC 10K and
10 additional temperature sensor characteristics.
PCD7.L410Analogue output module, 4 channels 0…10 VDC,
with local override functionality
PCD7.L452Analogue data encoder for local control variables :
local override functionality Auto/On/Off,
potentiometer 0…10 VDC,
local override, auto acknowledge,
LED indicator,
11.2 mm overall width, spring terminals
PCD7.L490Labelling plate for PCD7.L452 module
Price for 10 pieces
PCD7.L500Power supply 230 VAC / 24 VDC
for supply of all RAIL and SAFE modules,
input 110…240 VAC, output 24 VDC / 700 mA,
for max. 15 RAIL or SAVE modules
PCD7.L600-1Room controller 230 VAC with 2 triac outputs,
1 relay for electrical heating,
3-stage fan speed control and
light & sunblind functionality
PCD7.L601-1Room controller 230 VAC with 2 triac outputs,
2 outputs 0…10 V, 1 relay for electrical heating,
3-stage or variable fan speed control,
with additional air quality control
and light & sunblind functionality
PCD7.L603-1Room controller 24 VAC with 2 triac outputs,
2 outputs 0…10 V, 1 relay for electrical heating,
3-stage (230 VAC) or variable fan speed control,
with additional air quality control
and light & sunblind functionality
PCD7.L604-1Room controller 230 VAC with 2 triac outputs,
2 outputs 0…10 V, incl. 24 VAC (7 W) supply,
1 relay for electrical heating,
3-stage or variable fan speed control,
with additional air quality control
and light & sunblind functionality
PCD7.L610Room controller 230 VAC with 2 triac outputs,
1 relay for electrical heating and
3-stage fan speed control
PCD7.L611Room controller 230 VAC with 2 triac outputs,
2 outputs 0…10 V, 1 relay for electrical heating
and 3-stage fan speed control
PCD7.L614Room controller 230 VAC with 2 triac outputs,
2 outputs 0…10 V, incl. 24 VAC (7 W) supply,
1 relay for electrical heating and
3-stage or variable fan speed control
PCD7.L615Double room controller 230 VAC for radiator/cooling
ceiling combinations and VAV applications
with 4 triac outputs, 2 outputs 0…10 V,
2 relays for electrical heating and autonomous
interfaces for digital room control units
PCD7.L616Room controller 230 VAC for air quality control
with 2 triac outputs, 2 outputs 0…10 V,
1 relay for electrical heating,
3-stage or variable fan speed control,
control accuracy eu.bac certified
PCD7.L630Temperature sensor
PCD7.L631Temperature sensor and setpoint adjustment
PCD7.L632Temperature sensor, setpoint adjustment,
presence-tip-switch and LED
PCD7.L640Temperature sensor and setpoint adjustment
PCD7.L641Temperature sensor, setpoint adjustment,
presence-tip-switch and LED
PCD7.L642Temperature sensor, setpoint adjustment,
presence-tip-switch, LED and fanspeed control
PCD7.L644Temperature sensor, function keys and
LCD display with programmable functions
for HVAC, light & shade
PCD7.L645BTouch screen room operator unit, black,
for PCD7.L6xx room controllers
PCD7.L645WTouch screen room operator unit, white,
for PCD7.L6xx room controllers
PCD7.L651EnOcean radio receiver for connecting Thermokon
room control devices and EnOcean wireless switches
PCD7.L660IR (infrared) remote control unit with LCD display,
temperature sensor and wall mount adapter
for fixed mounting
PCD7.L661IR (infrared) receiver
PCD7.L662Radio remote control unit with LCD display,
temperature sensor and wall mount adapter
for fixed mounting
PCD7.L663Radio receiver
PCD7.L665IR (infrared) receiver with multi sensor
for presence and brightness for PCD7.L660
PCD7.L670Connection cable for digital room control units,
RJ9 / RJ9, length 10 m
PCD7.L670-30Connection cable for digital room control units,
RJ9 / RJ9, length 30 m
PCD7.L670-50Connection cable for digital room control units,
RJ9 / RJ9, length 50 m
PCD7.L671Connection cable for analogue room control units,
RJ11 / open cable strand, length 10 m
PCD7.L790NCompact room controller 24 VAC with
1 triac output for thermal valves (PWM),
2 digital inputs and integrated temperature
sensor (without user controls)
PCD7.L791NCompact room controller 24 VAC with
2 triac outputs for thermal valves (PWM),
2 digital inputs and integrated temperature
sensor (without user controls)
PCD7.L792NCompact room controller 24 VAC with
2 triac outputs for 2 thermal valves (PWM) or
1 valve 3-point (open/close), 2 digital inputs,
integrated temperature sensor and analogue user
interface for setpoint adjustment and presence
PCD7.L793NCompact room controller 24 VAC with
2 triac outputs for 2 thermal valves (PWM) or
1 valve 3-point (open/close), 2x 0…10 V outputs,
2 digital inputs, integrated temperature sensor
and analogue user interface for setpoint adjustment
and presence
PCD7.LRL2BACnet MS/TP room controller,
230 VAC power supply, large housing,
2 analogue outputs, 4 triac outputs,
4 relays, 1 LED output, 6 universal inputs
PCD7.LRL2-P5Programmable room controller,
S-Bus, Modbus,
230 VAC power supply, large housing, RTC,
2 analogue outputs, 4 triac outputs,
4 relays, 1 LED output, 6 universal inputs
PCD7.LRL4-P5Programmable room controller,
S-Bus, Modbus,
230 VAC power supply, large housing, RTC,
6 analogue outputs, 4 triac outputs,
4 relays, 1 LED output, 10 universal inputs
PCD7.LRL5-P5Programmable room controller,
S-Bus, Modbus,
24 VAC power supply, large housing, RTC,
6 analogue outputs, 4 triac outputs,
4 relays, 1 LED output, 10 universal inputs
PCD7.L-RoomUPAndroid App license
for commissioning
PCD7.LRS4BACnet MS/TP room controller,
230 VAC power supply, small housing,
4 analogue outputs, 2 triac outputs,
4 relays, 1 LED output, 4 universal inputs
PCD7.LRS4-P5Programmable room controller,
S-Bus, Modbus,
230 VAC power supply, small housing, RTC,
4 analogue outputs, 2 triac outputs,
4 relays, 1 LED output, 4 universal inputs
PCD7.LRS5BACnet MS/TP room controller,
24 VAC power supply, small housing,
4 analogue outputs, 2 triac outputs,
4 relays, 1 LED output, 4 universal inputs
PCD7.LRS5-P5Programmable room controller,
S-Bus, Modbus,
24 VAC power supply, small housing, RTC,
4 analogue outputs, 2 triac outputs,
4 relays, 1 LED output, 4 universal inputs
PCD7.LR-TR40Wall module,
temperature sensor,
SYLK-Bus interface
PCD7.LR-TR40-CO2Wall module,
temperature and CO2 sensors,
SYLK-Bus interface
PCD7.LR-TR40-HWall module,
temperature and humidity sensors,
SYLK-Bus interface
PCD7.LR-TR40-H-CO2Wall module,
temperature, humidity and CO2 sensors,
SYLK-Bus interface
PCD7.LR-TR42Wall module with LCD display,
temperature sensor,
SYLK-Bus interface
PCD7.LR-TR42-CO2Wall module with LCD display,
temperature and CO2 sensors,
SYLK-Bus interface
PCD7.LR-TR42-HWall module with LCD display,
temperature and humidity sensors,
SYLK-Bus interface
PCD7.LR-TR42-H-CO2Wall module with LCD display,
temperature, humidity and CO2 sensors,
SYLK-Bus interface
PCD7.R550M04Flash memory module with 4 MByte file system
(for user program backup, web pages, ..),
for PCD1.M2xxx, PCD2.M5xxx and
PCD3.M5xxx/..M6xxx
(plug-in onto slot M1 or M2) ;
can also be used into PCD3.F1xx module
PCD7.R551M04Flash memory module 4 MByte
with 1 MByte as backup for the user program
and 3 MByte with file system,
for PCD2.M5xxx and PCD3.M5xxx/..M6xxx
(plug-in onto slot M1 or M2)
PCD7.R562Flash memory module for BACnet® firmware
with 128 MByte file system
(for user program backup, web pages, ..),
for PCD1.M2xxx, PCD2.M4xxx/..M5xxx and
PCD3.M5xxx/..M6xxx
(plug-in onto slot M1 or M2)
PCD7.R582Flash memory module for LON-IP firmware
with 128 MByte file system
(for user program backup, web pages, ..),
for PCD1.M2xxx, PCD2.M4xxx/..M5xxx and
PCD3.M5xxx/..M6xxx
(plug-in onto slot M1 or M2)
PCD7.R610Basic module for uSD Flash memory card,
plug-in onto slot M1 or M2
(Saia PCD® uSD card not included)
PCD7.R-MSD1024Saia PCD® uSD Flash memory card 1024 MByte
(included SD Flash adapter)
PCD7.R-SD1024Saia PCD® SD Flash memory card 1024 MByte
PCD7.R-SD512Saia PCD® SD Flash memory card 512 MByte
PCD7.T161Termination box for RS-485 line,
with galvanic isolation, 230 VAC
PCD7.T162Termination box for RS-485 line,
with galvanic isolation, 24 VDC
PCD7.W600Analogue output module, 4 channels, 12 bits,
0…10 V, to be connected on PCD1 and
PCD2.M4x60 onto slot A
PCD8.BACnet-Eye-1BACnet explorer software tool for
professional analysis and diagnostics
of building automation networks.
License valid for 1 user
PCD8.OPC-1S-Bus OPC-Server – Full version
for 1 PC and one (1) application
PCD8.OPC-3S-Bus OPC-Server – Full version
for 3 PCs with the same application
PCD8.OPC-5S-Bus OPC-Server – Full version
for 5 PCs with the same application
PCD8.PG5-CORESaia PG5® Core Package
Programming software with editors
(IL, Fupla, Graftec), network configurators,
standard libraries (analogue, communication,
arithmetic & logic, wide area, file system),
application libraries (alarming, blinds-lighting,
e-mail, trending (HDLog), energy meter, FTP Client,
DALI, Modbus, EIB, EnOcean, JCI N2-Bus),
Web Editor and Fbox Builder (basic version),
incl. Visi.Plus Engineering Edition
PCD8.PG5-DEMOSaia PG5® Demo
Demo version with all functions
Runtime limited to 90 days
(download free of charge at www.sbc-support.com)
PCD8.PG5-ENDUSERSaia PG5® End-User License
The end customer is supported by the creator of
the installation (according to customer’s key)
PCD8.PG5-EXTENDEDSaia PG5® Extended Package
Same as Saia PG5® HVAC Package
with in addition the library DDC Suite
PCD8.PG5-FBOXBLDSaia PG5® FBox Builder  (advanced version)
Software package for Saia PG5® FBox Builder
IL knowledge needed and
1 day’s training included
PCD8.PG5-HVACSaia PG5® HVAC Package
Same as Saia PG5® Core Package with in addition
the libraries (HVAC, Belimo MP-Bus, LonWorks®,
Room Controller, Modem) and BACnet configurator
PCD8.PG5-UPGRADESaia PG5® Software Upgrade
Upgrade according to customer’s key
– version 2.2 to 2.3
PCD8.PG5-UPGR-EXTDSaia PG5® Software Upgrade
Upgrade from HVAC to Extended package
PCD8.PG5-UPGR-HVACSaia PG5® Software Upgrade
Upgrade from Core to HVAC package
PCD8.SUP-10000Saia PCD® Supervisor basic package incl. S-Bus driver,
10’000 database points
PCD8.SUP-10000OPENExtend base license,
with additional 10’000 open protocol points,
(BACnet IP, EIB/KNX IP, LON IP, Modbus IP,
M-Bus IP, SNMP)
PCD8.SUP-100EXTSaia PCD® Supervisor extension,
additional 100 S-Bus database points
PCD8.SUP-15000EXTSaia PCD® Supervisor extension,
additional 15’000 S-Bus database points
PCD8.SUP-2500Saia PCD® Supervisor basic package incl. S-Bus driver,
2’500 database points
PCD8.SUP-2500EXTSaia PCD® Supervisor extension,
additional 2’500 S-Bus database points
PCD8.SUP-2500OPENExtend base license,
with additional 2’500 open protocol points,
(BACnet IP, EIB/KNX IP, LON IP, Modbus IP,
M-Bus IP, SNMP)
PCD8.SUP-500Saia PCD® Supervisor basic package incl. S-Bus driver,
500 database points
PCD8.SUP-5000EXTSaia PCD® Supervisor extension,
additional 5’000 S-Bus database points
PCD8.SUP-5000OPENExtend base license,
with additional 5’000 open protocol points,
(BACnet IP, EIB/KNX IP, LON IP, Modbus IP,
M-Bus IP, SNMP)
PCD8.SUP-500OPENExtend base license,
with additional 500 open protocol points,
(BACnet IP, EIB/KNX IP, LON IP, Modbus IP,
M-Bus IP, SNMP)
PCD8.SUP-DB-CSVExtend the capability for the Supervisor,
to interact with Microsoft Excel
PCD8.SUP-DB-SQLExtend the capability for the supervisor,
to communicate with SQL Server
PCD8.SUP-MNT1Saia PCD® Supervisor maintenance upgrade,
additional 1 year
PCD8.SUP-MNT3Saia PCD® Supervisor maintenance upgrade,
additional 3 year
PCD8.SUP-MNT5Saia PCD® Supervisor maintenance upgrade,
additional 5 year
PCD8.SUP-NAA-ENGSaia PCD® Supervisor,
additional engineering license
PCD8.SUP-NAA-RENSaia PCD® Supervisor,
annual agreement renewal
PCD8.SUP-NAA-STKSaia PCD® Supervisor Starter kit,
annual agreement (5 engineers)
PCD8.SUP-NAA-UPGSaia PCD® Supervisor,
annual agreement upgrade
PCD8.SUP-OPCExtend the open protocol points,
with OPC client connectivity
PCD8.VP-BACNETBACnet driver
Driver for up to 2’500 BACnet objects
PCD8.VP-BACNET10BACnet driver
Driver for up to 10’000 BACnet objects
PCD8.VP-BASICVisi.Plus Basic – Basic package
Data management system, database system,
graphical editor, engineering tool,
scheduler program, trend and alarm capture,
MALM remote alarms via SMS/e-mail,
PRT access logging and SBC S-Driver for
10’000 data points (approx. 650 hardware data points)
PCD8.VP-ESPAESPA 4.4.4 – Receive alarms and
messages via ESPA protocol to Visi.Plus
PCD8.VP-GE10GE10 – Graphical editor
Runtime system, ten additional operator stations
PCD8.VP-GE2GE2 – Graphical editor
Runtime system, two additional operator stations
PCD8.VP-GE5GE5 – Graphical editor
Runtime system, five additional operator stations
PCD8.VP-MALMMALM – Remote alarms via SMS/e-mail
(included in Basic and Standard package)
PCD8.VP-MALMESPAMALM ESPA 4.4.4 – Remote alarms (sending)
via ESPA protocol
(add-on option for MALM)
PCD8.VP-MINIVisi.Plus Mini – Mini package
Data management system, database system,
graphical editor, engineering tool,
scheduler program, trend and alarm capture
and SBC S-Driver for 1’000 data points
(approx. 65 hardware data points)
PCD8.VP-OPC1OPC1 – OPC Client
Client for 250 data points
PCD8.VP-OPC2OPC2 – OPC Client
Client for 1’000 data points
PCD8.VP-OPC3OPC3 – OPC Client
Client for 10’000 data points
PCD8.VP-PCALCpCalc – Calculation for energy analysis
and system monitoring,
up to 1’000 formulas with 16 variables each
PCD8.VP-PCHARTpChart – Trend display tool
Each user (1..10) costs a full pChart license
(one user included in the Standard package)
PCD8.VP-PRTPRT – Access Logging
(included in the Basic and Standard package)
PCD8.VP-SBUS10KOption for Visi.Plus packages
SBC S-Driver for 10’000 additional data points
(approx. 650 hardware data points)
PCD8.VP-SBUS25KOption for Visi.Plus packages
SBC S-Driver for 25’000 additional data points
(approx. 1’625 hardware data points)
Remark : not possible with the Mini package
PCD8.VP-SBUS50KOption for Visi.Plus packages
SBC S-Driver for 50’000 additional data points
(approx. 3’250 hardware data points)
Remark : not possible with the Mini package
PCD8.VP-STDVisi.Plus Standard – Standard package
Data management system, database system,
graphical editor, engineering tool,
scheduler program, trend and alarm capture,
MALM remote alarms via SMS/e-mail,
PRT access logging, pChart trend display,
web server 2 HTML5
and SBC S-Driver for 100’000 data points
(approx. 6’500 hardware data points)
PCD8.VP-SWDONGLEVisi.Plus Software dongle license
A software dongle is a file that can be used
instead of hardware dongle.
The software dongle is specific to a licence and
a computer (IP address and hard drive number)
PCD8.VP-UPGRADEVisi.Plus Upgrade – Version upgrade
according to customer’s Visi.Plus package
– version 1.5 to 1.6/1.7
PCD8.VP-WA10Web-Server 10 based on HTML5
for 10 additional simultaneous connections
PCD8.VP-WA2Web-Server 2 based on HTML5
for 2 additional simultaneous connections
PCD8.VP-WA5Web-Server 5 based on HTML5
for 5 additional simultaneous connections
PCD8.VP-WA-UPGRWeb-Server Upgrade
Upgrade from old Web-Server (WEB)
to new (WA)
PMK-EEM400Kit for mounting ALE3/AWD3 energy meters
on door cabinet
Q.NET-5TXIndustrial Ethernet switch, 5 ports 10/100Base-TX,
24 VDC, DIN rail mounting
Q.NET-8TXIndustrial Ethernet switch, 8 ports 10/100Base-TX,
24 VDC, DIN rail mounting
Q.NET-CONAnnual license for the “SBC Connectivity Service”
portal
Q.NET-EBW-E100Industrial LAN router for VPN connection
.
Q.NET-EBW-H100Industrial 3G/HSPA router for VPN connection
.
Q.PS-AD1-2403Switch-mode power supply,
input 24 VAC, output 24 VDC / 3 A
Q.PS-AD1-2405Switch-mode power supply,
input 24 VAC, output 24 VDC / 5 A
Q.PS-AD2-2402FSwitch-mode power supply,
input 115…230 VAC, output 24 VDC / 2.5 A
Q.PS-AD2-2405FSwitch-mode power supply,
input 115…230 VAC, output 24 VDC / 5 A
Q.PS-AD2-2410FSwitch-mode power supply,
input 115…230 VAC, output 24 VDC / 10 A
Q.PS-AD3-2405FSwitch-mode power supply,
single or double-phase,
input 230 VAC or 400…500 VAC,
output 24 VDC / 5 A
Q.PS-ADB-2405-1Single-phase switch-mode power supply
with intelligent battery charger,
input 115…230 VAC, output 24 VDC / 5 A
Q.PS-BL2-2401CHCompact switch-mode power supply,
input 115…230 VAC, output 24 VDC / 1.25 A,
net cable 230 VAC with CH-connector
Q.PS-BL2-2401EUCompact switch-mode power supply,
input 115…230 VAC, output 24 VDC / 1.25 A,
net cable 230 VAC type IEC320
Q.PS-PEL-2401Switch-mode power supply for electrical sub-distributors,
input 110…240 VAC, output 24 VDC / 0.9 A
Q.PS-PEL-2403Switch-mode power supply for electrical sub-distributors,
input 110…240 VAC, output 24 VDC / 2.8 A
Q.RCU-A-TAnalogue room control unit,
temperature sensor
Q.RCU-A-TSAnalogue room control unit,
temperature sensor and setpoint adjustment
Q.RCU-A-TSOAnalogue room control unit,
temperature sensor, setpoint adjustment
and presence-tip-switch
Q.RCU-A-TSOFAnalogue room control unit,
temperature sensor, setpoint adjustment,
presence-tip-switch and fan control
T7460A1001Room control unit for PCD7.LRxx,
temperature sensor
T7460B1009Room control unit for PCD7.LRxx,
temperature sensor and setpoint adjustment
T7460C1007Room control unit for PCD7.LRxx,
temperature sensor, setpoint adjustment
and override
T7460D1005Room control unit for PCD7.LRxx,
temperature sensor, setpoint adjustment
and fan speed switch
T7460F1000Room control unit for PCD7.LRxx,
temperature sensor, setpoint adjustment,
override and fan speed switch
TR40Wall module,
temperature sensor,
SYLK-Bus interface
TR40-CO2Wall module,
temperature and CO2 sensors,
SYLK-Bus interface
TR42Wall module with LCD display,
temperature sensor,
setpoint adjustment,
override and fan control,
SYLK-Bus interface
TR42-CO2Wall module with LCD display,
temperature and CO2 sensors,
setpoint adjustment,
override and fan control,
SYLK-Bus interface
Back to Saia Burgess