Product List
Part Number | Description |
3 230 9178-001 | Fixation set (4 pieces) for Web panel with embedded Micro-Browser |
3 230 9178-002 | Fixation set (6 pieces) for Web panel with embedded Micro-Browser |
4 104 7420 0 | Lead sealing cap for energy meters AAD1 and ALD1 |
4 104 7485 0 | Lead sealing cap for energy meters AAE1, AAE3, ALE3 and AWD3 |
4 104 7493 0 | Cover for PCD3.M5xxx and ..M6xxx |
4 104 7502 0 | Slot cover for unused PCD3 I/O slots (neutral – without SBC logo) |
4 104 7515 0 | Slot cover for unused PCD3 I/O slots (with SBC logo) |
4 104 7719 0 | Cover for PCD2.M5x40 without SBC logo (with neutral front cover) |
4 104 7720 0 | Cover for PCD2.C2000 without SBC logo (with neutral front cover) |
4 104 7758 0 | Cover for PCD2.C1000 without SBC logo (with neutral front cover) |
4 104 7759 0 | Cover for PCD1.M2xxx without SBC logo (with neutral front cover) |
4 121 4910 0 | Additional fixation set (4 pieces) for hollow (cavity) in-wall mounting of the MB web panel 5.7″ |
4 310 8686 0 | Pre-printed adhesive strips for snap on holder 4 329 4819 1 |
4 310 8723 0 | Labelling clip set containing – 10 snap on transparent label holders (label clip) – 2 sheets of neutral pre-cut inscription labels (DIN A4) |
4 310 8750 0 | Spare part for Web panel PCD7.D457VTCF True brushed aluminum front overlay |
4 310 8755 0 | Spare part for Web panel PCD7.D457VTCF Black and sparkling front overlay |
4 310 8756 0 | Spare part for Web panel PCD7.D457VTCF Front overlay with mirror effect |
4 329 4819 1 | Snap on holder for module marking Set of 10 pieces |
4 405 4847 0 | Plug-in screw terminal block 10-pole, labelling 0…9 or for I/O module |
4 405 4869 0 | Plug-in screw terminal block 14-pole, for PCD2.A250 module |
4 405 4916 0 | Plug-in screw terminal block 10-pole, labelling 0…9 |
4 405 4917 0 | Plug-in screw terminal block 10-pole, labelling 10…19 |
4 405 4918 0 | Plug-in screw terminal block 10-pole, labelling 20…29 |
4 405 4919 0 | Plug-in screw terminal block 10-pole, labelling 30…39 |
4 405 4920 0 | Plug-in screw terminal block 10-pole, labelling 40…49 |
4 405 4921 0 | Plug-in screw terminal block 10-pole, labelling 40…49 |
4 405 4933 0 | Plug-in I/O spring terminal block, 6-pole up to 2.5 mm2, labelled 1 to 6, for Web panel with embedded Micro-Browser |
4 405 4934 0 | Plug-in I/O spring terminal block, 8-pole up to 1.5 mm2, labelled 1 to 8, for manual control module PCD3.W800, connector type “J” |
4 405 4936 0 | Plug-in I/O spring terminal block, 12-pole up to 1.5 mm2, labelled 1 to 12, for manual control module PCD3.A810, connector type “F” |
4 405 4952 0 | Plug-in screw terminal block, 2-pole up to 2.5 mm2 (orange block) for PCD3.C200 and PCD3.T760 |
4 405 4954 0 | Plug-in I/O spring terminal block, 10-pole up to 2.5 mm2, labelled 0 to 9, for modules with 4, 6 or 8 I/Os, connector type “A” |
4 405 4956 0 | Plug-in I/O spring terminal block, 2×12-pole up to 1.0 mm2, labelled 0 to 23, for modules with 16 I/Os or relay module ..A251, connector type “C” |
4 405 4995 0 | Plug-in spring terminal block, 8-pole up to 2.5 mm2 (orange block) for PCD3.M2/..M3/..M5/.M6 and PCD3.T66x |
4 405 4998 0 | Plug-in I/O spring terminal block, 14-pole up to 1.5 mm2, labelled 0 to 13, for complex modules (e.g. weighing modules), connector type “E” |
4 405 5027 0 | Plug-in I/O spring terminal block, 4-pole up to 2.5 mm2, labelled 1 to 4, for light and shade control module PCD3.A860, connector type “G” |
4 405 5028 0 | Plug-in I/O spring terminal block, 2×3-pole up to 1.0 mm2, labelled 1 to 6, for light and shade control module PCD3.A860, connector type “H” |
4 405 5048 0 | Plug-in spring terminal block, 2×5-pole up to 1.0 mm2 (orange block), labelled 0 to 9, also for PCD2.G200, connector type “K” |
4 405 5054 0 | Plug-in spring terminal block, 2×5-pole up to 1.0 mm2 (black block), also for PCD2.G200 |
4 405 5055 0 | Plug-in screw terminal block 10-pole, labelling 30…39 |
4 405 5056 0 | Plug-in screw terminal block 10-pole, labelling 29…20 |
4 405 5057 0 | Plug-in screw terminal block 10-pole, labelling 19…10 |
4 405 5066 0 | Plug-in I/O spring terminal block with LED, only for digital I/O 24 VDC (transistors), 10-pole up to 1.5 mm2 |
4 405 5079 0 | Plug-in I/O spring terminal block with LED, only for digital I/O 24 VDC (transistors), 3x 10-pole (3 wire connection) up to 1.5 mm2 |
4 405 5087 0 | Plug-in screw terminal block 9-pole, labelling 11…19 |
4 405 5088 0 | Plug-in screw terminal block 10-pole, labelling 20…29 |
4 405 5089 0 | Plug-in screw terminal block 11-pole, labelling 0…10 |
4 405 5109 0 | Plug-in screw terminal block 9-pole for PCD2.F2400 |
4 507 4817 0 | Lithium battery for PCD processor units (RENATA button type CR 2032) |
4 639 4898 0 | Battery carrier module for PCD2.M4xxx and PCD3.M5xxx/..M6xxx |
AAD1D5F10KR3A00 | Single-phase energy meter (7-digit) S0 pulse output = 1’000 pulses/kWh Imax = 32 A, according to MID directive |
AAE1D5F10KR3A00 | Single-phase energy meter (7-digit) S0 pulse output = 1’000 pulses/kWh Imax = 65 A, according to MID directive |
AAE3D5F10PR3A00 | Three-phase energy meter (7-digit) S0 pulse output = 100 pulses/kWh Imax = 65 A, 1 tariff, according to MID directive |
AAE3D5F11PR3A00 | Three-phase energy meter (7-digit) S0 pulse output = 100 pulses/kWh Imax = 65 A, 2 tariffs, according to MID directive |
ALD1B5F10KA3A00 | Single-phase two-way energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 32 A according to MID directive display of active power, voltage and current |
ALD1B5FD00A3A00 | Single-phase two-way energy meter with LCD display Modbus interface, Imax = 32 A display of active power, voltage and current according to MID directive |
ALD1B5FS00A3A00 | Single-phase two-way energy meter with LCD display S-Bus interface, Imax = 32 A display of active power, voltage and current according to MID directive |
ALD1D5F10KA3A00 | Single-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive |
ALD1D5F10KB3A00 | Single-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 32 A, 1 tariff, according to MID directive |
ALD1D5FD00A3A00 | Single-phase energy meter with LCD display Modbus interface, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive |
ALD1D5FD00A3A44 | Single-phase energy meter with LCD display Modbus interface, parity 8N1, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive |
ALD1D5FM00A3A00 | Single-phase energy meter with LCD display M-Bus interface, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive |
ALD1D5FS00A3A00 | Single-phase energy meter with LCD display S-Bus interface, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive |
ALE3B5F10KC3A00 | Three-phase two-way energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 65 A display of active power, voltage and current display without main power (backup) according to MID directive |
ALE3B5FD00C3A00 | Three-phase two-way energy meter with LCD display Modbus interface, Imax = 65 A display of active power, voltage and current according to MID directive |
ALE3B5FM00C3A00 | Three-phase two-way energy meter with LCD display M-Bus interface, Imax = 65 A display of active power, voltage and current according to MID directive |
ALE3B5FS00C3A00 | Three-phase two-way energy meter with LCD display S-Bus interface, Imax = 65 A display of active power, voltage and current according to MID directive |
ALE3D5F10KA3A00 | Three-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 65 A, 1 tariff display of active power, voltage and current according to MID directive |
ALE3D5F10KB3A00 | Three-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 65 A, 1 tariff according to MID directive |
ALE3D5F11KC3A00 | Three-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 65 A, 2 tariffs display of active power, voltage and current display without main power (backup) according to MID directive |
ALE3D5FD10C3A00 | Three-phase energy meter with LCD display Modbus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive |
ALE3D5FD10C3A44 | Three-phase energy meter with LCD display Modbus interface, parity 8N1, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive |
ALE3D5FM10C3A00 | Three-phase energy meter with LCD display M-Bus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive |
ALE3D5FS10C3A00 | Three-phase energy meter with LCD display S-Bus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive |
AWD3B5W10MC3A00 | Three-phase two-way energy meter with LCD display S0 pulse output = 10 pulses/kWh 5…1’500 A display of active power, voltage and current according to MID directive |
AWD3B5WS00C3A00 | Three-phase two-way energy meter with LCD display S-Bus interface, 5…1’500 A display of active power, voltage and current according to MID directive |
AWD3D5W10MC3A00 | Three-phase energy meter with LCD display S0 pulse output = 10 pulses/kWh 5…1’500 A, 1 tariff display of active power, voltage and current according to MID directive |
AWD3D5W10ND3A00 | Three-phase energy meter with LCD display S0 pulse output = 1 pulse/kWh 1’000…6’000 A, 1 tariff display of active power, voltage and current according to MID directive |
AWD3D5WD00C3A00 | Three-phase energy meter with LCD display Modbus interface, 5…1’500 A, 1 tariff display of active power, voltage and current according to MID directive |
AWD3D5WD00C3A44 | Three-phase energy meter with LCD display Modbus interface, parity 8N1, 5…1’500 A, 1 tariff display of active power, voltage and current according to MID directive |
AWD3D5WM00C3A00 | Three-phase energy meter with LCD display M-Bus interface, 5…1’500 A, 1 tariff display of active power, voltage and current according to MID directive |
AWD3D5WS00C3A00 | Three-phase energy meter with LCD display S-Bus interface, 5…1’500 A, 1 tariff display of active power, voltage and current according to MID directive |
BACA-A | WiFi access point with BACnet IP to MS/TP router with Honeywell Logo |
CJ211 | 11-pole socket (47.0 x 47.0 x 20.0 mm) for flush mounting, connection with screw terminals |
CJ250 | 11-pole socket (46.8 x 46.8 x 20.0 mm) for screw mounting or snap-on mounting on 35 mm DIN rail, connection with screw terminals |
Documentation | The Saia PCD® technical documentation is available on our support homepage (download free of charge at www.sbc-support.com) |
EMD1L5F1KA00 | Single-phase energy meter with LCD display S0 pulse output = 1’000 pulses/kWh Imax = 32 A, 1 tariff |
IRM-RLC | 10 terminal covers for PCD7.LRLx controllers |
IRM-RSC | 10 terminal covers for PCD7.LRSx controllers |
KFD11JVTN | DC/DC isolating amplifier, galvanic isolation, Input ranges 0…10 VDC or 0…20 mA Output ranges 0…10 VDC or 0…20 mA |
KFD12JVTN | DC/DC isolating amplifier, galvanic isolation, Input ranges 0…75 VDC or 0…60 mV Output ranges 0…10 VDC or 0…20 mA |
KFE102NE1N | Voltage monitoring relay 230 VAC, 50/60 Hz memory function, parameterisable, 1 relay (change-over contact) |
KFE103NE1N | Current monitoring relay 230 VAC, 50/60 Hz memory function, parameterisable, 1 relay (change-over contact) |
KFE300NE9N | Phase monitoring relay 3 x 400 VAC, 50/60 Hz analog setting 1 relay (change-over contact) |
KFE302NE9N | Three-phase voltage monitoring relay (AC) 3 x 400 VAC, 50/60 Hz memory function, analog setting, 1 relay (change-over contact) |
KFT100JE1N | Temperature monitoring relay 230 VAC, 50/60 Hz, up to 6 PTC, automatic reset, 1 relay (make contact) |
KFT200KE1N | Temperature monitoring relay 230 VAC, 50/60 Hz, up to 6 PTC memory function, manual or automatic reset 1 relay (change-over contact) |
KOL251H7MKVPN00 | Electronic timer KOL 24…48 VDC and 24…240 VAC 4 time ranges 0.15 s to 10 min Star-delta timer |
KOL311H7MRVPN00 | Electronic timer KOL 24…48 VDC and 24…240 VAC 6 time ranges 0.05 s to 10 h Delayed operation |
KOL312H7MRVPN00 | Electronic timer KOL 24…48 VDC and 24…240 VAC 6 time ranges 0.05 s to 10 h Delayed release |
KOL321H7MRVPN00 | Electronic timer KOL 24…48 VDC and 24…240 VAC 6 time ranges 0.05 s to 10 h Fleeting-on delay timer |
KOL342H7MRVPN00 | Electronic timer KOL 24…48 VDC and 24…240 VAC 6 time ranges 0.05 s to 10 h Flasher relay, pulse starting |
KOL360H7MRVPN00 | Electronic timer KOL 24…48 VCC and 24…240 VCA 6 time ranges 0.05 s to 10 h Multifunction |
KOP111J7MWVPN00 | Electronic timer KOP.J L24…48 VDC and 24…240 VAC 10 time ranges 0.05 to 60 h Delayed operation |
KOP112J7MWVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC 10 time ranges 0.05 to 60 h Delayed release |
KOP119K7MWVAN00 | Electronic timer KOP.K 24…240 VDC/VAC 4 time ranges 0.15 s to 10 min Power off delayed release 1 changeover contact |
KOP128J7BAVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC Time range 0.05 s to 1 s Watch dog |
KOP128J7CAVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC Time range 0.15 s to 3 s Watch dog |
KOP128J7EAVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC Time range 0.5 s to 10 s Watch dog |
KOP160J7MWVAN00 | Electronic timer KOP.J 24…240 VDC/VAC 10 time ranges 0.05 s to 60 h Multifunction |
KOP160J7MWVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC 10 time ranges 0.05 s to 60 h Multifunction |
KOP170J7MWVPN00 | Electronic timer KOP.J 24…48 VDC and 24…240 VAC 10 time ranges 0.05 s to 60 h Asymmetric pulse generator |
KOP219K7MWVAN00 | Electronic timer KOP.K 24…240 VDC/VAC 4 time ranges 0.15 s to 10 min Power off delayed release 1 changeover contacts |
KOP260F0MWVAN00 | Electronic timer KOP.F 24…230 VDC/VAC 12 time ranges 0.01 s to 10 h Multifunction |
KOP511K7MWVPN00 | Electronic timer KOP.K 24…48 VDC and 24…240 VAC 10 time ranges 0.05 s to 60 h Delayed operation |
KOP512K7MWVPN00 | Electronic timer KOP.K 24…48 VDC and 24…240 VAC 10 time ranges 0.05 s to 60 h Delayed release |
KOP560K7MWVAN00 | Electronic timer KOP.K 24…240 VAC/VDC 10 time ranges 0.05 s to 60 h Multifunction |
KOP560K7MWVPN00 | Electronic timer KOP.K 24…48 VDC and 24…240 VAC 10 time ranges 0.05 s to 60 h Multifunction |
PCD1.A1000-A20 | E-Line digital output module manual override operating level for all outputs status LED for outputs supply 24 VDC 10 digital outputs 24 VDC (12…32 VDC/0.5 A) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.A2000-A20 | E-Line digital output module manual override operating level for all outputs status LED for outputs supply 24 VDC 6 relay normally open 230 VAC / 30 VDC, 16 A (resistive load) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.B1000-A20 | E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 4 digital inputs 24 VDC (source operation) 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.B1010-A20 | E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 24 digital inputs 24 VDC (source operation) 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.B1020-A20 | E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 16 digital inputs 24 VDC (source operation) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.B5000-A20 | E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 6 digital inputs 115…230 VAC 3 relay normally open 230 VAC / 30 VDC, 6 A (resistive load) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.E1000-A10 | E-Line digital input module status LED for inputs supply 24 VDC 12 digital inputs 24 VDC (source operation) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.F2611-C15 | Programmable E-Line DALI module for up to 64 DALI ballasts with integrated DALI-Bus power supply supply 24 VAC/VDC 4 digital inputs 24 VAC/VDC 4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (service) |
PCD1.G1100-C15 | Programmable E-Line input/output module for light and sunblind control supply 24 VAC/VDC 4 digital inputs 24 VAC/VDC 2 relay changeover 230 VAC / 30 VDC, 8 A, max. inrush current 15 A, incl. galvanically isolated current measurement 2 analogue outputs 12 bits, 0…10 V (3 mA max.) 3 interfaces: RS-485 (S-Bus), USB & NFC (service) |
PCD1.G2000-A20 | E-Line combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 6 universal digital/analogue inputs – digital inputs 24 VDC – analoque inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 2 analogue outputs 10 bits, 0…10 V 2 triac outputs 24 VAC/1A or 230 VAC/1A 1 interface RS-485 (S-Bus and Modbus) |
PCD1.G3600-C15 | Programmable E-Line input/output module for room automation supply 24 VAC/VDC 8 digital inputs 24 VAC/VDC 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A 4 triac outputs 24 VCA/1A or 230 VAC/1 A 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (3 mA max.) 3 interfaces: RS-485 (S-Bus), USB & NFC (service) |
PCD1.G3601-C15 | Programmable E-Line input/output module for room automation with auxiliary RS-485 interface supply 24 VAC/VDC 8 digital inputs 24 VAC/VDC 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A 4 triac outputs 24 VCA/1A or 230 VAC/1 A 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (3 mA max.) 4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (service) |
PCD1.G5000-A20 | E-Line combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 16 digital inputs 24 VDC (source operation) 4 relay normally open 230 VAC / 30 VDC, 4 A (resistive load) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 8 analogue inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (10 mA max.) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.G5010-A20 | E-Line combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 12 digital inputs 24 VDC (source operation) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 12 analogue inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 8 analogue outputs 12 bits, 0…10 V (10 mA max.) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.G5020-A20 | E-Line combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC 8 digital inputs 24 VDC (source operation) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 16 analogue inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (10 mA max.) 1 interface RS-485 (S-Bus and Modbus) |
PCD1.K0206-005 | E-line cover and labelling set consisting of 5 covers (105 mm) and labelling sheets for installation in automation control cabinets |
PCD1.K0206-025 | E-line cover and labelling set consisting of 5 covers (105 mm) with holes for the manual override operating level and labelling sheets for installation in automation control cabinets |
PCD1.M0160E0 | Saia PCD® E-Controller with Ethernet TCP/IP, Energy controller with S-Monitoring function for electrical cabinet, web and FTP server, file system, CPU with 1 MByte user program (RAM), backup memory, 1 MByte RAM DB/Text, on-board 128 MByte Flash memory, USB port for PG5, no I/O module sockets, on-board I/O : – 2 interrupt inputs, 1 output (PWM) – 12 digital I/O (4I/4O/4 configurable) – 2 analogue inputs (12 bits), clock (RTC), data protection 1-3 years, RS-485 (up to 115 kbits/s), 1 port (socket A) for PCD7.F1xxS |
PCD1.M2110R1 | Saia PCD1.Room with Ethernet TCP/IP for room automation and heavac applications, web and FTP server, file system, CPU with 256 KByte user program (RAM), backup memory, on-board 8 MByte Flash memory, USB port for PG5, up to 40 I/O, 1 free I/O module socket, on-board I/O (with fixed ..W525 on I/O slot 1) : – 2 interrupt inputs, 1 output (PWM) – 12 digital I/O (4I/4O/4 configurable) – 8 analogue I/O (6I/2O), clock (RTC), data protection 1-3 years, RS-485 (up to 115 kbits/s), 1 port (socket A) for PCD7.F1xxS, the Smart RIO Manager function is not supported, S-Bus and Modbus stations limited to max. 10 units |
PCD1.M2120 | PCD1 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program (RAM), backup memory, on-board 8 MByte Flash memory, USB port for PG5, up to 50 I/O, 2 I/O module sockets, on-board I/O : – 2 interrupt inputs, 1 output (PWM) – 12 digital I/O (4I/4O/4 configurable) – 2 analogue inputs (12 bits), clock (RTC), data protection 1-3 years, RS-485 (up to 115 kbits/s), 1 port (socket A) for PCD7.F1xxS |
PCD1.M2160 | PCD1 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program (RAM), backup memory, 1 MByte RAM DB/Text, on-board 128 MByte Flash memory, USB port for PG5, up to 50 I/O, 2 I/O module sockets, on-board I/O : – 2 interrupt inputs, 1 output (PWM) – 12 digital I/O (4I/4O/4 configurable) – 2 analogue inputs (12 bits), clock (RTC), data protection 1-3 years, RS-485 (up to 115 kbits/s), 1 port (socket A) for PCD7.F1xxS |
PCD1.M2220-C15 | E-Line processor unit with Ethernet TCP/IP for electrical switch cabinet, web and FTP server, file system, 512 KByte user program, 128 KByte RAM DB/Text, 128 MByte Flash memory, supply 24 VAC/VDC 2 I/O module sockets, 1 M socket, 4 digital inputs, 2 analogue inputs, 1 watchdog 4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (service) |
PCD1.P1001-J30 | Power Quality Analyser (PQA) with RS-485 interface LCD 128 x 64 monochrome 1.9″ LED for I/O and status supply 110…230 VAC 50/60 Hz measuring inputs 3PH+N up to 270 VAC 1 digital input 24 VDC, high active 1 digital output 5…24 VDC 2 relay normally open 230 VAC, 6 A (resistive load) 1 analogue input for Pt/Ni 1000 sensor 1 interface RS-485 (S-Bus/Modbus) with galvanic isolation |
PCD1.W5200-A20 | E-Line analogue output module manual override operating level for all outputs status LED for outputs supply 24 VDC 8 analogue outputs 10 bits, 0…10 V 1 interface RS-485 (S-Bus and Modbus) |
PCD1.W5300-C15 | Programmable E-Line input/output module for analogue applications supply 24 VAC/VDC 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm 4 analogue outputs 12 bits, 0…10 V (4 mA max.) 3 interfaces: RS-485 (S-Bus), USB & NFC (Service) |
PCD2.A200 | Digital output module, 4 relays, 250 VAC/2 A, ‘make’ contact, contact protection |
PCD2.A210 | Digital output module, 4 relays, 250 VAC/2 A, ‘break’ contact, contact protection |
PCD2.A220 | Digital output module, 2 x 3 relays, 250 VAC/2 A ‘make’ contact, without contact protection |
PCD2.A250 | Digital output module, 2 x 4 relays, 48 VAC/2 A or 50 VDC/2 A, ‘make’ contact, without contact protection |
PCD2.A300 | Digital output module, 6 outputs, transistors, 10…32 VDC/2 A |
PCD2.A400 | Digital output module, 8 outputs, transistors, 5…32 VDC/0.5 A |
PCD2.A410 | Digital output module, 8 outputs, transistors, 5…32 VDC/0.5 A, with galvanic isolation |
PCD2.A460 | Digital output module, 16 outputs, transistors, 10…32 VDC/0.5 A, ribbon cable connector for PCD2.K2xx |
PCD2.A465 | Digital output module, 16 outputs, transistors, 10…32 VDC/0.5 A, connection with spring terminals |
PCD2.B100 | Digital input/output module with 8 I/O, 2 inputs, 2 outputs and 4 configurable I/O’s Inputs : 24 VDC, source operation, delay 8 ms Outputs : breaking capacity 5…32 VDC/0.5 A |
PCD2.B160 | Digital input/output module with 16 I/O, configurable either as inputs or as outputs in groups of four (4) Inputs : 24 VDC, source operation, delay 0.2/8 ms Outputs : breaking capacity 5…30 VDC/0.5 A |
PCD2.C1000 | Extension housing with 4 I/O module sockets and 24 VDC power supply for PCD2.M4560 and PCD2.M5x40 |
PCD2.C2000 | Extension housing with 8 I/O module sockets and 24 VDC power supply for PCD2.M4560 and PCD2.M5x40 |
PCD2.E110 | Digital input module, 8 inputs, 24 VDC, source and sink operation, 8 ms input delay |
PCD2.E111 | Digital input module, 8 inputs, 24 VDC, source and sink operation, 0.2 ms input delay |
PCD2.E160 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 8 ms input delay, ribbon cable connector for PCD2.K2xx |
PCD2.E161 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 0.2 ms input delay, ribbon cable connector for PCD2.K2xx |
PCD2.E165 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 8 ms input delay, connection with spring terminals to max 0.5 mm2 |
PCD2.E166 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 0.2 ms input delay, connection with spring terminals to max 0.5 mm2 |
PCD2.E500 | Digital input module, 6 inputs, 110…240 VAC, with galvanic isolation, source operation |
PCD2.E610 | Digital input module, 8 inputs, 24 VDC, with galvanic isolation, source and sink operation, 8 ms delay |
PCD2.E611 | Digital input module, 8 inputs, 24 VDC, with galvanic isolation, source and sink operation, 0.2 ms delay |
PCD2.E613 | Digital input module, 8 inputs, 48 VDC, with galvanic isolation, source and sink operation, 9 ms delay |
PCD2.F2100 | Serial interface module with 1x RS-422 / RS-485 and 1 socket for PCD7.F1xxS module |
PCD2.F2150 | BACnet MS/TP serial interface module with 1x RS-422 / RS-485 and 1 socket for PCD7.F1xxS module |
PCD2.F2210 | Serial interface module with 1x RS-232 and 1 socket for PCD7.F1xxS module |
PCD2.F2400 | LonWorks® interface module (Lon FTT10) for up to 254 network variables and 1 socket for PCD7.F1xxS module |
PCD2.F2610 | DALI master interface module for up to 64 DALI ballasts, with integrated DALI-Bus power supply |
PCD2.F2700 | M-Bus master interface module for up to 240 M-Bus slave addresses freely distributable on 2 M-Bus interfaces |
PCD2.F2710 | M-Bus master interface module for up to 20 M-Bus slave addresses freely distributable on 2 M-Bus interfaces |
PCD2.F2720 | M-Bus master interface module for up to 60 M-Bus slave addresses freely distributable on 2 M-Bus interfaces |
PCD2.F2810 | Belimo MP-Bus interface module for up to 8 drives and 1 socket for PCD7.F1xxS module |
PCD2.G200 | Multifunction module (2 sockets side-by-side) with: 4 digital inputs, 24 VDC, 8 ms delay 4 digital outputs, 10…32 VDC/0.5 A, 8 analogue inputs, 12 bits, for – 2x 0…10 V, – 2x Pt/Ni 1000, – 4x selectable via jumper as 0…10 V, 0…20 mA or Pt/Ni 1000 8 analogue outputs, 10 bits, 0…10 V |
PCD2.H112 | Intelligent fast counting module, 150 kHz, 2 counting channels for incremental sensor inputs |
PCD2.H114 | Intelligent fast counting module, 150 kHz, 4 counting channels for incremental sensor inputs |
PCD2.H150 | Absolute encoder module with SSI interface and 4 outputs 24 VDC/0.5 A |
PCD2.H222 | Pulse output module for 2 independent stepper motor axes |
PCD2.H310 | Positioning module for 1 servomotor axis, encoder input 24 VDC/100 kHz, setpoint output ±10 V (12 bits) |
PCD2.H311 | Positioning module for 1 servomotor axis, encoder input 5 VDC/100 kHz, setpoint output ±10 V (12 bits) |
PCD2.K010 | I/O bus connector for PCD2.M4560 to PCD2.Cx000 or PCD2.Cx000 to PCD2.Cx000 |
PCD2.K106 | Extension cable for PCD2.M5x40 to PCD2.C1000/..C2000 or PCD3.Cxx0 (length 0.9 m – from version C) |
PCD2.K221 | Plug-in system cable for digital modules with 16 I/Os. Sheathed, round cable, length 1.5 m (type D); PCD side: 34-pole ribbon cable connector Process side: strand ends free, colour-coded |
PCD2.K223 | Plug-in system cable for digital modules with 16 I/Os. Sheathed, round cable, length 3.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: strand ends free, colour-coded |
PCD2.K231 | Plug-in system cable for terminal adapters PCD2.K520/..K521/..K525. Sheathed, half-round cable, length 1.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: 34-pole ribbon cable connector |
PCD2.K232 | Plug-in system cable for terminal adapters PCD2.K520/..K521/..K525. Sheathed, half-round cable, length 2.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: 34-pole ribbon cable connector |
PCD2.K241 | Plug-in system cable for 2 terminal adapters PCD2.K51x or relay interface PCD2.K55x. Sheathed, half-round cable, length 1.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: two 16-pole ribbon cable connectors |
PCD2.K241 | Plug-in system cable for 2 terminal adapters PCD2.K51x or relay interface PCD2.K55x. Sheathed, half-round cable, length 1.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: two 16-pole ribbon cable connectors |
PCD2.K242 | Plug-in system cable for 2 terminal adapters PCD2.K51x or relay interface PCD2.K55x. Sheathed, half-round cable, length 2.0 m (type D); PCD side: 34-pole ribbon cable connector Process side: two 16-pole ribbon cable connectors |
PCD2.K271 | Plug-in system cable for analogue I/O modules and ..H modules. Sheathed, screened, round cable, length 1.5 m; PCD side: 10-pole, plug-in screw terminal block Process side: strand ends free, numbered |
PCD2.K510 | Ribbon / screw terminal adapter for 8 inputs or 8 outputs, without LEDs; PCD side: 16-pole ribbon connector Process side: 2 x 6 screw terminals |
PCD2.K511 | Ribbon / screw terminal adapter for 8 inputs or 8 outputs, with LEDs (source operation); PCD side: 16-pole ribbon connector Process side: 2 x 6 screw terminals |
PCD2.K520 | Ribbon / screw terminal adapter for 16 inputs or 16 outputs, without LEDs; PCD side: 34-pole ribbon connector Process side: 2 x 10 screw terminals |
PCD2.K521 | Ribbon / screw terminal adapter for 16 inputs or 16 outputs, with LEDs (source operation); PCD side: 34-pole ribbon connector Process side: 2 x 10 screw terminals |
PCD2.K525 | Ribbon / screw terminal adapter for 16 inputs or 16 outputs, with LEDs (source operation); PCD side: 34-pole ribbon connector Process side: 3 x 16 screw terminals |
PCD2.K551 | Relay interface module for 8 transistor outputs, with LEDs; PCD side: screw terminals or 16-pole ribbon connector Process side: 24 screw terminals |
PCD2.K552 | Relay interface module for 8 transistor outputs, with LEDs, manual control mode (switch on-off-auto) and 1 output feedback signal of manual mode; PCD side: screw terminals or 16-pole ribbon connector Process side: 24 screw terminals |
PCD2.M4160 | PCD2 processor unit with Ethernet TCP/IP, web and FTP server, file system, 512 kByte user program, 128 kByte RAM DB/Text, 8 MByte Flash memory, 4 I/O module sockets (2 for PCD2.F2xxx), clock (RTC), interfaces: Ethernet, USB, RS-485 (187.5 Kbits/s), 1 slot A for PCD7.F1xxS |
PCD2.M4560 | PCD2 processor unit with Ethernet TCP/IP, web and FTP server, file system, 2 MByte user program, 1 MByte RAM DB/Text, 128 MByte Flash memory, 4 I/O module sockets, expandable up to 1024 I/O, clock (RTC), interfaces: Ethernet, USB, RS-485 (187.5 kbits/s), RS-485 (1.5 Mbits/s), 1 slot A for PCD7.F1xxS, 1 slot C for Profibus or CAN |
PCD2.M5540 | PCD2 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program (RAM), 1x Ethernet TCP/IP (2x RJ45 switch), USB port for PG5, up to 1024 I/O, expandable with PCD2.Cxx0 or PCD3.Cxx0, 8 I/O module sockets, on-board I/O: 6 interrupt inputs, 2 outputs (PWM), clock (RTC), data protection 1-3 years, RS-232, RS-485 (115 kbits/s), Profi-S-Net/MPI, 3 sockets A1/A2/C for communication modules |
PCD2.R6000 | Basic module for SD Flash memory card, for PCD2.M5xxx, plug-in onto I/O slot 0…3 (Saia PCD® SD card not included) |
PCD2.W200 | Analogue input module, 8 channels, 10 bits, 0…10 V |
PCD2.W210 | Analogue input module, 8 channels, 10 bits, 0…20 mA |
PCD2.W220 | Analogue input module, 8 channels, 10 bits, Pt/Ni 1000 |
PCD2.W220Z02 | Analogue input module, 8 channels, 10 bits, NTC10 temperature sensors |
PCD2.W220Z12 | Analogue input module, 8 channels, 10 bits, 4 inputs 0…10 V and 4 inputs Pt/Ni 1000 |
PCD2.W300 | Analogue input module, 8 channels, 12 bits, 0…10 V |
PCD2.W305 | Analogue input module with galvanic isolation, 7 channels, 12 bits, 0…10 V |
PCD2.W310 | Analogue input module, 8 channels, 12 bits, 0…20 mA |
PCD2.W315 | Analogue input module with galvanic isolation, 7 channels, 12 bits, 0(4)…20 mA |
PCD2.W325 | Analogue input module with galvanic isolation, 7 channels, 12 bits, ±10 V |
PCD2.W340 | Universal analogue input module, 8 channels, 12 bits, 0…10 V, 0…2.5 V, 0…20 mA, Pt/Ni 1000 |
PCD2.W350 | Analogue input module, 8 channels, 12 bits, Pt/Ni 100 |
PCD2.W360 | Analogue input module, 8 channels, 12 bits, Pt 1000 (-50…+150°C, 0.1°C) |
PCD2.W380 | Universal analogue input module, 8 channels, 13 bits (12 bits+sign), selectable by software, 0…10 V, ±10 V, 0…20 mA, ±20 mA, Pt/Ni 1000, 0…2500 Ohm, 0…300 kOhm (for NTC sensors) |
PCD2.W400 | Analogue output module, 4 channels, 8 bits, 0…10 V |
PCD2.W410 | Analogue output module, 4 channels, 8 bits, 0…10 V / 0…20 mA / 4…20 mA, jumper selectable |
PCD2.W525 | Analogue combined input/output module with galvanic isolation, 6 channels : 4 inputs, 14 bits, 0…10 V, 0(4)…20 mA, Pt 1000, Pt 500 or Ni 1000 (selectable by DIP switch) and 2 outputs, 12 bits, 0…10 V or 0(4)…20 mA (selectable by software (FBox, FB) |
PCD2.W600 | Analogue output module, 4 channels, 12 bits, 0…10 V |
PCD2.W605 | Analogue output module with galvanic isolation, 6 channels, 10 bits, 0…10 V |
PCD2.W610 | Analogue output module, 4 channels, 12 bits, 0..10 V / ± 10V / 0…20 mA |
PCD2.W615 | Analogue output module with galvanic isolation, 4 channels, 10 bits, 0(4)…20 mA |
PCD2.W625 | Analogue output module with galvanic isolation, 6 channels, 10 bits, ±10 V |
PCD2.W720 | Weighing module with 2 systems for up to 6 weighing cells, resolution 18 bits |
PCD2.W745 | Universal temperature measurement module for up to 4 measuring inputs, resolution 16 bits, for TC Type J & K and 4 wires Pt/Ni 100/1000 |
PCD3.A200 | Digital output module, 4 relays, 250 VAC/2 A, ‘make’ contact, contact protection (connector type A included) |
PCD3.A210 | Digital output module, 4 relays, 250 VAC/2 A, ‘break’ contact, contact protection (connector type A included) |
PCD3.A220 | Digital output module, 2 x 3 relays, 250 VAC/2 A ‘make’ contact, without contact protection (connector type A included) |
PCD3.A251 | Digital output module, 8 relays, 48 VAC/2 A or 50 VDC/2 A with 6 change-over contacts and 2 make-contacts (connector type C included) |
PCD3.A300 | Digital output module, 6 outputs, transistors, 10…32 VDC/2 A (connector type A included) |
PCD3.A400 | Digital output module, 8 outputs, transistors, 5…32 VDC/0.5 A (connector type A included) |
PCD3.A410 | Digital output module, 8 outputs, transistors, 5…32 VDC/0.5 A, with galvanic isolation (connector type A included) |
PCD3.A460 | Digital output module, 16 outputs, transistors, 10…32 VDC/0.5 A, ribbon cable connector for PCD2.K2xx |
PCD3.A465 | Digital output module, 16 outputs, transistors, 10…32 VDC/0.5 A (connector type C included) |
PCD3.A810 | Digital local control module with 4 relays outputs – 2 ‘changeover’ contacts – 2 ‘make’ contacts Connection with PCD3.K810 (connector type F included) |
PCD3.A860 | Light and shade control module with – 2 relays outputs 250 VAC/12 A – 2 digital inputs 24 VDC Connection with PCD3.K86x (connector type G and H included) |
PCD3.B100 | Digital input/output module with 8 I/O, 2 inputs, 2 outputs and 4 configurable I/O’s Inputs : 24 VDC, source operation, delay 8 ms Outputs : breaking capacity 5…32 VDC/0.5 A (connector type A included) |
PCD3.B160 | Digital input/output module with 16 I/O, configurable either as inputs or as outputs in groups of four (4) Inputs : 24 VDC, source operation, delay 0.2/8 ms Outputs : breaking capacity 5…30 VDC/0.5 A (2 connectors type K included) |
PCD3.C100 | Extension module holder for 4 I/O modules |
PCD3.C110 | Extension module holder for 2 I/O modules |
PCD3.C110Z09 | Extension module holder for 2 I/O modules for compact controllers Saia PCD3 |
PCD3.C200 | Extension module holder for 4 I/O modules with terminal connectors for external 24 VDC power supply |
PCD3.C200Z09 | Extension module holder for 4 I/O modules with terminal connectors for external 24 VDC power supply for compact controllers Saia PCD3 |
PCD3.E009 | Empty module housing for unused PCD3 I/O slots |
PCD3.E110 | Digital input module, 8 inputs, 24 VDC, source and sink operation, 8 ms input delay. (connector type A included) |
PCD3.E111 | Digital input module, 8 inputs, 24 VDC, source and sink operation, 0.2 ms input delay (connector type A included) |
PCD3.E160 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 8 ms input delay, ribbon cable connector for PCD2.K2xx |
PCD3.E161 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 0.2 ms input delay, ribbon cable connector for PCD2.K2xx |
PCD3.E165 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 8 ms input delay, (connector type C included) |
PCD3.E166 | Digital input module, 16 inputs, 24 VDC, source and sink operation, 0.2 ms input delay, (connector type C included) |
PCD3.E500 | Digital input module, 6 inputs, 110…240 VAC, with galvanic isolation, source operation, 20 ms input delay (connector type A included) |
PCD3.E610 | Digital input module, 8 inputs, 24 VDC, with galvanic isolation, source and sink operation, 10 ms input delay (connector type A included) |
PCD3.E613 | Digital input module, 8 inputs, 48 VDC, with galvanic isolation, source and sink operation, 9 ms delay (connector type A included) |
PCD3.F110 | Serial interface module RS-422 / RS-485 (connector type A included) |
PCD3.F121 | Serial interface module RS-232 up to 115.2 kBit/s, suitable for modem connection (connector type A included) |
PCD3.F150 | Serial interface module RS-485 with galvanic isolation (connector type A included) |
PCD3.F180 | Belimo MP-Bus interface module, max. 8 actuators and sensors connectable (connector type A included) |
PCD3.F210 | Serial interface module with 1x RS-422 / RS-485 and 1 socket for PCD7.F1xxS module (2 connectors type K included) |
PCD3.F215 | BACnet MS/TP serial interface module with 1x RS-422 / RS-485 and 1 socket for PCD7.F1xxS module (2 connectors type K included) |
PCD3.F221 | Serial interface module with 1x RS-232 and 1 socket for PCD7.F1xxS module (2 connectors type K included) |
PCD3.F240 | LonWorks® interface module (Lon FTT10) for up to 254 network variables and 1 socket for PCD7.F1xxS module (connector type A included) |
PCD3.F261 | DALI master interface module for up to 64 DALI ballasts, with integrated DALI-Bus power supply (connector type A included) |
PCD3.F270 | M-Bus master interface module for up to 240 M-Bus slave addresses freely distributable on 2 M-Bus interfaces (connector type A included) |
PCD3.F271 | M-Bus master interface module for up to 20 M-Bus slave addresses freely distributable on 2 M-Bus interfaces (connector type A included) |
PCD3.F272 | M-Bus master interface module for up to 60 M-Bus slave addresses freely distributable on 2 M-Bus interfaces (connector type A included) |
PCD3.F281 | Belimo MP-Bus interface module for up to 8 drives and 1 socket for PCD7.F1xxS module (2 connectors type K included) |
PCD3.H112 | Intelligent fast counting module, 150 kHz, 2 counting channels for incremental sensor inputs (2 connectors type K included) |
PCD3.H114 | Intelligent fast counting module, 150 kHz, 4 counting channels for incremental sensor inputs (2 connectors type K included) |
PCD3.H150 | Absolute encoder module with SSI interface and 4 outputs 24 VDC/0.5 A (connector type A included) |
PCD3.H222 | Pulse output module for 2 independent stepper motor axes (2 connectors type K included) |
PCD3.H310 | Positioning module for 1 servomotor axis, encoder input 24 VDC/100 kHz, setpoint output ±10 V (12 bits) (connector type A included) |
PCD3.H311 | Positioning module for 1 servomotor axis, encoder input 5 VDC/100 kHz, setpoint output ±10 V (12 bits) (connector type A included) |
PCD3.K010 | Connection plug PCD3.M/T/C to PCD3.Cxx0 |
PCD3.K106 | Extension cable for PCD2.M4560 to PCD2.Cx000, PCD3.M/T/C to PCD3.Cxx0 or PCD2.C1000/..C2000 to PCD2.C1000/..C2000 (length 0.7 m) |
PCD3.K116 | Extension cable for PCD2.M4560 to PCD2.Cx000, PCD3.M/T/C to PCD3.Cxx0 or PCD2.C1000/..C2000 to PCD2.C1000/..C2000 (length 1.2 m) |
PCD3.M2130V6 | PCD3 Compact with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program (RAM), backup with on-board Flash memory, 1 MByte on-board Flash memory for file system, USB port for PG5, 2 interrupt inputs, RS-485, 32 digital I/O (20I/12O), 6 analogue I/O (4I/2O), 1 port (socket A) for PCD7.F1xxS, data protection 1-3 years |
PCD3.M2330A4T5 | PCD3 WAC with GSM/GPRS modem & Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program (RAM), backup with on-board Flash memory, 1 MByte on-board Flash memory for file system, slot for SD Flash memory card, USB port for PG5, 2 interrupt inputs, RS-485, 10 digital I/O (8I/2O), 4 analogue I/O (4I/0O), 1 port (socket A) for PCD7.F1xxS, data protection 1-3 years |
PCD3.M3120 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 128 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus |
PCD3.M3160 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus |
PCD3.M3330 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus |
PCD3.M3360 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus |
PCD3.M5340 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus |
PCD3.M5360 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus, data protection 1-3 years |
PCD3.M5540 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus |
PCD3.M5560 | PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupts, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus |
PCD3.M6560 | PCD3 processor unit with Profibus DP Master and Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-485 for Profi-S-Net/MPI/S-Bus |
PCD3.M6860 | PCD3 processor unit with 2 Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus |
PCD3.M6880 | PCD3 Standby processor unit with 2 Ethernet TCP/IP and Co-processor for Standby operation, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus |
PCD3.R010 | Battery module for PCD3.M3xxx, plug-in onto I/O Slot #3 |
PCD3.R562 | Flash memory module for BACnet® firmware with 128 MByte file system (for user program backup, web pages, ..), for PCD3.Mxxxx with Ethernet TCP/IP (plug-in onto I/O slot 0…3) |
PCD3.R600 | Basic module for SD Flash memory card, plug-in onto I/O slot 0…3 (Saia PCD® SD card not included) |
PCD3.S100 | Input/Output Simulator for PCD3.M/.T/.C (for ex. for test assembly or workshop models) |
PCD3.T665 | Smart-RIO, Ether-S-IO data exchange, programmable, 32 KByte program memory, up to 256 I/O, 2 Interrupts, web server |
PCD3.T666 | Smart-RIO, Ether-S-IO data exchange, programmable, 128 KByte program memory, up to 256 I/O, 2 Interrupts, web server and on-board RS-485 interface |
PCD3.T668 | Smart-RIO for Standby processor unit, Ether-S-IO data exchange, programmable, 128 KByte program memory, up to 256 I/O, 2 Interrupts, web server and on-board RS-485 interface |
PCD3.W200 | Analogue input module, 8 channels, 10 bits, 0…10 V (connector type A included) |
PCD3.W210 | Analogue input module, 8 channels, 10 bits, 0…20 mA (connector type A included) |
PCD3.W220 | Analogue input module, 8 channels, 10 bits, Pt/Ni 1000 (connector type A included) |
PCD3.W220Z03 | Analogue input module, 8 channels, 10 bits, NTC10 temperature sensors (connector type A included) |
PCD3.W220Z12 | Analogue input module, 8 channels, 10 bits, 4 inputs 0…10 V and 4 inputs Pt/Ni 1000 (connector type A included) |
PCD3.W300 | Analogue input module, 8 channels, 12 bits, 0…10 V (connector type A included) |
PCD3.W305 | Analogue input module with galvanic isolation, 7 channels, 12 bits, 0…10 V (connector type E included) |
PCD3.W310 | Analogue input module, 8 channels, 12 bits, 0…20 mA (connector type A included) |
PCD3.W315 | Analogue input module with galvanic isolation, 7 channels, 12 bits, 0(4)…20 mA (connector type E included) |
PCD3.W325 | Analogue input module with galvanic isolation, 7 channels, 12 bits, ±10 V (connector type E included) |
PCD3.W340 | Universal analogue input module, 8 channels, 12 bits, 0…10 V, 0…2.5 V, 0…20 mA, Pt/Ni 1000 (connector type A included) |
PCD3.W350 | Analogue input module, 8 channels, 12 bits, Pt/Ni 100 (connector type A included) |
PCD3.W360 | Analogue input module, 8 channels, 12 bits, Pt 1000 (-50…+150°C, 0.1°C) (connector type A included) |
PCD3.W380 | Universal analogue input module, 8 channels, 13 bits (12 bits+sign), selectable by software, 0…10 V, ±10 V, 0…20 mA, ±20 mA, Pt/Ni 1000, 0…2500 Ohm, 0…300 kOhm (for NTC sensors) (2 connectors type K included) |
PCD3.W400 | Analogue output module, 4 channels, 8 bits, 0…10 V (connector type A included) |
PCD3.W410 | Analogue output module, 4 channels, 8 bits, 0…10 V / 0…20 mA / 4…20 mA, jumper selectable (connector type A included) |
PCD3.W525 | Analogue combined input/output module with galvanic isolation, 6 channels : 4 inputs, 14 bits, 0…10 V, 0(4)…20 mA, Pt 1000, Pt 500 or Ni 1000 (selectable by DIP switch) and 2 outputs, 12 bits, 0…10 V or 0(4)…20 mA (selectable by software (FBox, FB) (connector type E included) |
PCD3.W600 | Analogue output module, 4 channels, 12 bits, 0…10 V (connector type A included) |
PCD3.W605 | Analogue output module with galvanic isolation, 6 channels, 10 bits, 0…10 V (connector type E included) |
PCD3.W610 | Analogue output module, 4 channels, 12 bits, 0…10 V / ±10 V / 0…20 mA (connector type A included) |
PCD3.W615 | Analogue output module with galvanic isolation, 4 channels, 10 bits, 0(4)…20 mA (connector type E included) |
PCD3.W625 | Analogue output module with galvanic isolation, 6 channels, 10 bits, ±10 V (connector type E included) |
PCD3.W720 | Weighing module with 2 systems for up to 6 weighing cells, resolution 18 bits (connector type E included) |
PCD3.W745 | Universal temperature measurement module for up to 4 measuring inputs, resolution 16 bits, for TC Type J & K and 4 wires Pt/Ni 100/1000 (with soldered I/O spring terminal block) |
PCD3.W800 | Analogue local control module with 4 channels – 3 outputs 0..10 V with local control – 1 output 0..10 V without local control Connection with PCD3.K800 (connector type J included) |
PCD7.D170 | Small terminal with 5 keys for front panel flush mounting with display of 4 x 16 characters, RS 232 |
PCD7.D230 | Terminal for front panel flush mounting (IP 54), single-knob control, graphic LCD display of 8 x 20 characters, RS-232 / RS-422 / RS-485 |
PCD7.D230Z11 | Terminal for front panel flush mounting PCD7.D230 without SBC logo |
PCD7.D231 | Terminal for front panel flush mounting (IP 65), with 10 function keys, graphic LCD display of 8 x 20 characters, RS-232 / RS-422 / RS-485 |
PCD7.D231Z11 | Terminal for front panel flush mounting PCD7.D231 without SBC logo |
PCD7.D232 | Terminal for front panel flush mounting (IP 65), with 25 function keys, 8 LED; graphic LCD display of 8 x 20 characters, RS-232 / RS-422 / RS-485 |
PCD7.D232Z11 | Terminal for front panel flush mounting PCD7.D232 without SBC logo |
PCD7.D410-IWS | Kit for in-wall mounting of the Micro-Browser Web panels 10.4″ |
PCD7.D410-OWS | Kit for on-wall mounting of the Micro-Browser Web panels 10.4″ |
PCD7.D410VT5F | Programmable Web panel with embedded Micro-Browser, Base line 10.4″ TFT VGA, 640 x 480 pixels, 65’536 colours with touch screen, transmissive LED backlight, programmable with Saia PG5® tool, 128 MByte on-board file system, web and FTP server, 2x Ethernet TCP/IP (switch), RS-485 and socket for PCD7.F1xxS, for front panel flush mounting |
PCD7.D410VT5Z11 | Programmable Web panel PCD7.D410VT5F with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D410VTCF | Web panel with embedded Micro-Browser, Base line 10.4″ TFT VGA, 640 x 480 pixels, 65’536 colours with touch screen, transmissive CCFL backlight, 4 MByte on-board file system, FTP server, Ethernet TCP/IP, PS/2 and printer interfaces, for front panel flush mounting. |
PCD7.D410VTCZ11 | Web panel PCD7.D410VTCF with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D412DT5F | Programmable Web panel with embedded Micro-Browser, Base line 12.1″ TFT SVGA, 800 x 600 pixels, 65’536 colours with touch screen, transmissive LED backlight, programmable with Saia PG5® tool, 128 MByte on-board file system, web and FTP server, 2x Ethernet TCP/IP (switch), RS-485 and socket for PCD7.F1xxS, for front panel flush mounting |
PCD7.D412DT5Z11 | Programmable Web panel PCD7.D412DT5F with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D412DTPF | Web panel with embedded Micro-Browser, Base line 12.1″ TFT SVGA, 800 x 600 pixels, 65’536 colours with touch screen, transmissive LED backlight, 128 MByte on-board file system, FTP server, 2x Ethernet TCP/IP (switch), for front panel flush mounting. |
PCD7.D412DTPZ11 | Web panel PCD7.D412DTPF with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D412-IWS | Kit for in-wall mounting of the Micro-Browser Web panels 12.1″ |
PCD7.D412-OWS | Kit for on-wall mounting of the Micro-Browser Web panels 12.1″ |
PCD7.D443WT5R | Programmable Room Web panel with embedded Micro-Browser, black housing Base line 4.3″ TFT WQVGA, 480 x 272 pixels, 65’536 colours with touch screen, transmissive LED backlight, programmable with Saia PG5® tool, 128 MByte on-board file system, web and FTP server, temperature sensor, Ethernet TCP/IP, RS-485, for in-wall mounting |
PCD7.D443WT5RW | Programmable Room Web panel with embedded Micro-Browser, black housing Base line 4.3″ TFT WQVGA, 480 x 272 pixels, 65’536 colours with touch screen, transmissive LED backlight, programmable with Saia PG5® tool, 128 MByte on-board file system, web and FTP server, temperature sensor, Ethernet TCP/IP, RS-485, for in-wall mounting |
PCD7.D443WTPR | Room Web panel with embedded Micro-Browser, black housing, Base line 4.3″ TFT WQVGA, 480 x 272 pixels, 65’536 colours with touch screen, transmissive LED backlight, 4MByte on-board file system, FTP server, temperature sensor, Ethernet TCP/IP, for in-wall mounting |
PCD7.D443WTPRW | Room Web panel with embedded Micro-Browser, white housing, Base line 4.3″ TFT WQVGA, 480 x 272 pixels, 65’536 colours with touch screen, transmissive LED backlight, 4MByte on-board file system, FTP server, temperature sensor, Ethernet TCP/IP, for in-wall mounting |
PCD7.D450WTPF | Web panel with embedded Micro-Browser, Base line 5.0″ TFT WVGA, 800 x 480 pixels, 65’536 colours with touch screen, transmissive LED backlight, 128 MByte on-board file system, FTP server, Ethernet TCP/IP, for front panel flush mounting |
PCD7.D450WTPZ11 | Web panel PCD7.D450WTPF with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D457-IWS2 | Kit for in-wall mounting of the Micro-Browser Web panels 5.7″ and 7″ |
PCD7.D457-OWS | Kit for on-wall mounting of the Micro-Browser Web panels 5.7″ and 7″ |
PCD7.D457-OWS1 | Kit for on-wall mounting of the Micro-Browser Web panels 5.7″ and 7″ with space for power supply |
PCD7.D457-OWS2 | Kit for on-wall mounting of the Micro-Browser Web panels 5.7″ and 7″ |
PCD7.D457VT5F | Programmable Web panel with embedded Micro-Browser, Base line 5.7″ TFT VGA, 640 x 480 pixels, 65’536 colours with touch screen, transmissive LED backlight, programmable with Saia PG5® tool, 128 MByte on-board file system, web and FTP server, 2x Ethernet TCP/IP (switch), RS-485 and socket for PCD7.F1xxS, for front panel flush mounting |
PCD7.D457VT5Z11 | Programmable Web panel PCD7.D457VT5F with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D457VTCF | Web panel with embedded Micro-Browser, Base line 5.7″ TFT VGA, 640 x 480 pixels, 65’536 colours with touch screen, transmissive LED backlight, 4 MByte on-board file system, FTP server, Ethernet TCP/IP, for front panel flush mounting |
PCD7.D457VTCZ11 | Web panel PCD7.D457VTCF with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D457VTCZ34 | Web panel PCD7.D457VTCF with embedded Micro-Browser, without front overlay |
PCD7.D457VTCZ35 | Web panel PCD7.D457VTCF with embedded Micro-Browser, with black and sparkling front overlay |
PCD7.D470WTPF | Web panel with embedded Micro-Browser, Base line 7.0″ TFT WVGA, 800 x 480 pixels, 65’536 colours with touch screen, transmissive LED backlight, 128 MByte on-board file system, FTP server, Ethernet TCP/IP, for front panel flush mounting |
PCD7.D470WTPZ11 | Web panel PCD7.D470WTPF with embedded Micro-Browser, with neutral laminated front overlay (without SBC logo and code) |
PCD7.D5120WTA010 | Web panel equipped with Windows CE : – 12″ TFT colour display and resistive touch – WXGA 1280 x 800 pixels – CPU Atom E640 1.0 GHz – 1 GByte RAM, 1x SD card slot – 1x Ethernet 10/100/100 Mbits/s – 1x Ethernet 10/100 Mbits/s – 3x USB 2.0 host interface – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.D5150WTA010 | Web panel equipped with Windows CE : – 15″ TFT colour display and resistive touch – WXGA 1280 x 800 pixels – CPU Atom E640 1.0 GHz – 1 GByte RAM, 1x SD card slot – 1x Ethernet 10/100/100 Mbits/s – 1x Ethernet 10/100 Mbits/s – 3x USB 2.0 host interface – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.D6120WTA010 | Web panel equipped with WES7 : – 12″ TFT colour display and resistive touch – WXGA 1280 x 800 pixels – CPU Atom E680 1.6 GHz – 2 GByte RAM, 1x SD card slot – 1x Ethernet 10/100/100 Mbits/s – 1x Ethernet 10/100 Mbits/s – 3x USB 2.0 host interface – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.D6150WTA010 | Web panel equipped with WES7 : – 15″ TFT colour display and resistive touch – WXGA 1280 x 800 pixels – CPU Atom E680 1.6 GHz – 2 GByte RAM, 1x SD card slot – 1x Ethernet 10/100/100 Mbits/s – 1x Ethernet 10/100 Mbits/s – 3x USB 2.0 host interface – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.D6150WTC010 | Panel PC equipped with WES7 : – 15″ TFT colour display and resistive touch – WXGA 1280 x 800 pixels – CPU Celeron 2x 1.6 GHz – 2 GByte RAM, iHDD – 2x Ethernet 10/100/100 Mbits/s – 4x USB 2.0 host interface – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.D6210WTI010 | Panel PC equipped with WES7 : – 21″ TFT colour display and resistive touch – WUXGA 1920 x 1080 pixels – CPU I7 4x 2.1 GHz – 4 GByte RAM, iHDD – 2x Ethernet 10/100/100 Mbits/s – 4x USB 2.0 host interface, – 2x D-SUB RS-232 + RS-485 combined – 24 VDC power supply |
PCD7.F110S | Serial interface module RS-422 / RS-485 . |
PCD7.F121S | Serial interface module RS-232 up to 115 kbit/s suitable for modem connection |
PCD7.F150S | Serial interface module RS-485 with galvanic isolation |
PCD7.F180S | Belimo MP-Bus interface module, max. 8 actuators and sensors connectable |
PCD7.F7500 | Profibus DP master interface, 12 MBaud, for PCD2.M5xxx onto socket C |
PCD7.H104D | Pulse counter for collecting, converting and transmitting S0 pulses via Modbus, with 4 S0 pulse inputs, powered by 230 VAC, 50/60 Hz |
PCD7.H104DZ44 | Pulse counter for collecting, converting and transmitting S0 pulses via Modbus, parity 8N1, with 4 S0 pulse inputs, powered by 230 VAC, 50/60 Hz |
PCD7.H104SE | Pulse counter for collecting, converting and transmitting S0 pulses via S-Bus, with 4 S0 pulse inputs, powered by 230 VAC, 50/60 Hz |
PCD7.K412 | Shielded interface connection cable RS-232 between PGU connector and terminal; D-type 9-pole at both ends, length 2.5 m |
PCD7.K413 | Shielded interface connection cable RS-232 with RTS/CTS between PGU connector and terminal; D-type 9-pole at both ends, length 2.5 m |
PCD7.K423 | Shielded interface connection cable RS-232 with RTS/CTS between RS-232 interface of PCD (wire ends free) and terminal (D-type 9-pole); length 2.5 m |
PCD7.K456 | Shielded interface connection cable RS-485 between RS-485 interface of PCD (wire ends free) and terminal (D-type 9-pole); length 5.0 m |
PCD7.K840 | GSM/UMTS (850/900/1800/1900/2100 MHz) antenna with magnetic foot and SMA connector |
PCD7.L100 | Digital input module, 4 inputs 24 VDC/VAC, with local override functionality |
PCD7.L110 | Digital input module, 4 inputs 24 VDC/VAC, without local override functionality |
PCD7.L120 | Digital input/output module, 4 inputs 24 VDC/VAC and 2 relay outputs 250 VAC, with local override and integrated light & sunblind functionality |
PCD7.L121 | Digital input/output module, 4 inputs 24 VDC/VAC and 2 relay outputs 250 VAC, with local override and integrated light & sunblind functionality (protection class IP 65) |
PCD7.L130 | Digital input module, 10 inputs 24 VDC/VAC |
PCD7.L200 | Digital output module, 4 relays 250 VAC/6 A, with local override functionality |
PCD7.L210 | Digital output module, 4 triac 24…250 VAC/0.8 A, with local override functionality |
PCD7.L252 | Changeover switch with local override functionality Auto/On/Off : 1 changeover switch max. 250 VDC/VAC/8 A, local override, auto acknowledge, LED indicator, 2 added terminals for jumpers, 11.2 mm overall width, spring terminals |
PCD7.L260 | Coupler module for two-stage motor control : mutually latched relay 250 VDC/VAC/4 A, local override, auto acknowledge, LED indicator, 22.5 mm overall width, screw terminals |
PCD7.L290 | Labelling plate for PCD7.L252 module Price for 10 pieces |
PCD7.L291 | Jumper for connection of the supply voltage of up to 10 modules PCD7.L252 and PCD7.L452 |
PCD7.L320 | Analogue input module with 8 universally configurable channels for 0 … 10 VDC or various passive and active temperature sensors such as Pt 1000, Ni 1000, NTC 10K and 10 additional temperature sensor characteristics. |
PCD7.L410 | Analogue output module, 4 channels 0…10 VDC, with local override functionality |
PCD7.L452 | Analogue data encoder for local control variables : local override functionality Auto/On/Off, potentiometer 0…10 VDC, local override, auto acknowledge, LED indicator, 11.2 mm overall width, spring terminals |
PCD7.L490 | Labelling plate for PCD7.L452 module Price for 10 pieces |
PCD7.L500 | Power supply 230 VAC / 24 VDC for supply of all RAIL and SAFE modules, input 110…240 VAC, output 24 VDC / 700 mA, for max. 15 RAIL or SAVE modules |
PCD7.L600-1 | Room controller 230 VAC with 2 triac outputs, 1 relay for electrical heating, 3-stage fan speed control and light & sunblind functionality |
PCD7.L601-1 | Room controller 230 VAC with 2 triac outputs, 2 outputs 0…10 V, 1 relay for electrical heating, 3-stage or variable fan speed control, with additional air quality control and light & sunblind functionality |
PCD7.L603-1 | Room controller 24 VAC with 2 triac outputs, 2 outputs 0…10 V, 1 relay for electrical heating, 3-stage (230 VAC) or variable fan speed control, with additional air quality control and light & sunblind functionality |
PCD7.L604-1 | Room controller 230 VAC with 2 triac outputs, 2 outputs 0…10 V, incl. 24 VAC (7 W) supply, 1 relay for electrical heating, 3-stage or variable fan speed control, with additional air quality control and light & sunblind functionality |
PCD7.L610 | Room controller 230 VAC with 2 triac outputs, 1 relay for electrical heating and 3-stage fan speed control |
PCD7.L611 | Room controller 230 VAC with 2 triac outputs, 2 outputs 0…10 V, 1 relay for electrical heating and 3-stage fan speed control |
PCD7.L614 | Room controller 230 VAC with 2 triac outputs, 2 outputs 0…10 V, incl. 24 VAC (7 W) supply, 1 relay for electrical heating and 3-stage or variable fan speed control |
PCD7.L615 | Double room controller 230 VAC for radiator/cooling ceiling combinations and VAV applications with 4 triac outputs, 2 outputs 0…10 V, 2 relays for electrical heating and autonomous interfaces for digital room control units |
PCD7.L616 | Room controller 230 VAC for air quality control with 2 triac outputs, 2 outputs 0…10 V, 1 relay for electrical heating, 3-stage or variable fan speed control, control accuracy eu.bac certified |
PCD7.L630 | Temperature sensor |
PCD7.L631 | Temperature sensor and setpoint adjustment |
PCD7.L632 | Temperature sensor, setpoint adjustment, presence-tip-switch and LED |
PCD7.L640 | Temperature sensor and setpoint adjustment |
PCD7.L641 | Temperature sensor, setpoint adjustment, presence-tip-switch and LED |
PCD7.L642 | Temperature sensor, setpoint adjustment, presence-tip-switch, LED and fanspeed control |
PCD7.L644 | Temperature sensor, function keys and LCD display with programmable functions for HVAC, light & shade |
PCD7.L645B | Touch screen room operator unit, black, for PCD7.L6xx room controllers |
PCD7.L645W | Touch screen room operator unit, white, for PCD7.L6xx room controllers |
PCD7.L651 | EnOcean radio receiver for connecting Thermokon room control devices and EnOcean wireless switches |
PCD7.L660 | IR (infrared) remote control unit with LCD display, temperature sensor and wall mount adapter for fixed mounting |
PCD7.L661 | IR (infrared) receiver |
PCD7.L662 | Radio remote control unit with LCD display, temperature sensor and wall mount adapter for fixed mounting |
PCD7.L663 | Radio receiver |
PCD7.L665 | IR (infrared) receiver with multi sensor for presence and brightness for PCD7.L660 |
PCD7.L670 | Connection cable for digital room control units, RJ9 / RJ9, length 10 m |
PCD7.L670-30 | Connection cable for digital room control units, RJ9 / RJ9, length 30 m |
PCD7.L670-50 | Connection cable for digital room control units, RJ9 / RJ9, length 50 m |
PCD7.L671 | Connection cable for analogue room control units, RJ11 / open cable strand, length 10 m |
PCD7.L790N | Compact room controller 24 VAC with 1 triac output for thermal valves (PWM), 2 digital inputs and integrated temperature sensor (without user controls) |
PCD7.L791N | Compact room controller 24 VAC with 2 triac outputs for thermal valves (PWM), 2 digital inputs and integrated temperature sensor (without user controls) |
PCD7.L792N | Compact room controller 24 VAC with 2 triac outputs for 2 thermal valves (PWM) or 1 valve 3-point (open/close), 2 digital inputs, integrated temperature sensor and analogue user interface for setpoint adjustment and presence |
PCD7.L793N | Compact room controller 24 VAC with 2 triac outputs for 2 thermal valves (PWM) or 1 valve 3-point (open/close), 2x 0…10 V outputs, 2 digital inputs, integrated temperature sensor and analogue user interface for setpoint adjustment and presence |
PCD7.LRL2 | BACnet MS/TP room controller, 230 VAC power supply, large housing, 2 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 6 universal inputs |
PCD7.LRL2-P5 | Programmable room controller, S-Bus, Modbus, 230 VAC power supply, large housing, RTC, 2 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 6 universal inputs |
PCD7.LRL4-P5 | Programmable room controller, S-Bus, Modbus, 230 VAC power supply, large housing, RTC, 6 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 10 universal inputs |
PCD7.LRL5-P5 | Programmable room controller, S-Bus, Modbus, 24 VAC power supply, large housing, RTC, 6 analogue outputs, 4 triac outputs, 4 relays, 1 LED output, 10 universal inputs |
PCD7.L-RoomUP | Android App license for commissioning |
PCD7.LRS4 | BACnet MS/TP room controller, 230 VAC power supply, small housing, 4 analogue outputs, 2 triac outputs, 4 relays, 1 LED output, 4 universal inputs |
PCD7.LRS4-P5 | Programmable room controller, S-Bus, Modbus, 230 VAC power supply, small housing, RTC, 4 analogue outputs, 2 triac outputs, 4 relays, 1 LED output, 4 universal inputs |
PCD7.LRS5 | BACnet MS/TP room controller, 24 VAC power supply, small housing, 4 analogue outputs, 2 triac outputs, 4 relays, 1 LED output, 4 universal inputs |
PCD7.LRS5-P5 | Programmable room controller, S-Bus, Modbus, 24 VAC power supply, small housing, RTC, 4 analogue outputs, 2 triac outputs, 4 relays, 1 LED output, 4 universal inputs |
PCD7.LR-TR40 | Wall module, temperature sensor, SYLK-Bus interface |
PCD7.LR-TR40-CO2 | Wall module, temperature and CO2 sensors, SYLK-Bus interface |
PCD7.LR-TR40-H | Wall module, temperature and humidity sensors, SYLK-Bus interface |
PCD7.LR-TR40-H-CO2 | Wall module, temperature, humidity and CO2 sensors, SYLK-Bus interface |
PCD7.LR-TR42 | Wall module with LCD display, temperature sensor, SYLK-Bus interface |
PCD7.LR-TR42-CO2 | Wall module with LCD display, temperature and CO2 sensors, SYLK-Bus interface |
PCD7.LR-TR42-H | Wall module with LCD display, temperature and humidity sensors, SYLK-Bus interface |
PCD7.LR-TR42-H-CO2 | Wall module with LCD display, temperature, humidity and CO2 sensors, SYLK-Bus interface |
PCD7.R550M04 | Flash memory module with 4 MByte file system (for user program backup, web pages, ..), for PCD1.M2xxx, PCD2.M5xxx and PCD3.M5xxx/..M6xxx (plug-in onto slot M1 or M2) ; can also be used into PCD3.F1xx module |
PCD7.R551M04 | Flash memory module 4 MByte with 1 MByte as backup for the user program and 3 MByte with file system, for PCD2.M5xxx and PCD3.M5xxx/..M6xxx (plug-in onto slot M1 or M2) |
PCD7.R562 | Flash memory module for BACnet® firmware with 128 MByte file system (for user program backup, web pages, ..), for PCD1.M2xxx, PCD2.M4xxx/..M5xxx and PCD3.M5xxx/..M6xxx (plug-in onto slot M1 or M2) |
PCD7.R582 | Flash memory module for LON-IP firmware with 128 MByte file system (for user program backup, web pages, ..), for PCD1.M2xxx, PCD2.M4xxx/..M5xxx and PCD3.M5xxx/..M6xxx (plug-in onto slot M1 or M2) |
PCD7.R610 | Basic module for uSD Flash memory card, plug-in onto slot M1 or M2 (Saia PCD® uSD card not included) |
PCD7.R-MSD1024 | Saia PCD® uSD Flash memory card 1024 MByte (included SD Flash adapter) |
PCD7.R-SD1024 | Saia PCD® SD Flash memory card 1024 MByte |
PCD7.R-SD512 | Saia PCD® SD Flash memory card 512 MByte |
PCD7.T161 | Termination box for RS-485 line, with galvanic isolation, 230 VAC |
PCD7.T162 | Termination box for RS-485 line, with galvanic isolation, 24 VDC |
PCD7.W600 | Analogue output module, 4 channels, 12 bits, 0…10 V, to be connected on PCD1 and PCD2.M4x60 onto slot A |
PCD8.BACnet-Eye-1 | BACnet explorer software tool for professional analysis and diagnostics of building automation networks. License valid for 1 user |
PCD8.OPC-1 | S-Bus OPC-Server – Full version for 1 PC and one (1) application |
PCD8.OPC-3 | S-Bus OPC-Server – Full version for 3 PCs with the same application |
PCD8.OPC-5 | S-Bus OPC-Server – Full version for 5 PCs with the same application |
PCD8.PG5-CORE | Saia PG5® Core Package Programming software with editors (IL, Fupla, Graftec), network configurators, standard libraries (analogue, communication, arithmetic & logic, wide area, file system), application libraries (alarming, blinds-lighting, e-mail, trending (HDLog), energy meter, FTP Client, DALI, Modbus, EIB, EnOcean, JCI N2-Bus), Web Editor and Fbox Builder (basic version), incl. Visi.Plus Engineering Edition |
PCD8.PG5-DEMO | Saia PG5® Demo Demo version with all functions Runtime limited to 90 days (download free of charge at www.sbc-support.com) |
PCD8.PG5-ENDUSER | Saia PG5® End-User License The end customer is supported by the creator of the installation (according to customer’s key) |
PCD8.PG5-EXTENDED | Saia PG5® Extended Package Same as Saia PG5® HVAC Package with in addition the library DDC Suite |
PCD8.PG5-FBOXBLD | Saia PG5® FBox Builder (advanced version) Software package for Saia PG5® FBox Builder IL knowledge needed and 1 day’s training included |
PCD8.PG5-HVAC | Saia PG5® HVAC Package Same as Saia PG5® Core Package with in addition the libraries (HVAC, Belimo MP-Bus, LonWorks®, Room Controller, Modem) and BACnet configurator |
PCD8.PG5-UPGRADE | Saia PG5® Software Upgrade Upgrade according to customer’s key – version 2.2 to 2.3 |
PCD8.PG5-UPGR-EXTD | Saia PG5® Software Upgrade Upgrade from HVAC to Extended package |
PCD8.PG5-UPGR-HVAC | Saia PG5® Software Upgrade Upgrade from Core to HVAC package |
PCD8.SUP-10000 | Saia PCD® Supervisor basic package incl. S-Bus driver, 10’000 database points |
PCD8.SUP-10000OPEN | Extend base license, with additional 10’000 open protocol points, (BACnet IP, EIB/KNX IP, LON IP, Modbus IP, M-Bus IP, SNMP) |
PCD8.SUP-100EXT | Saia PCD® Supervisor extension, additional 100 S-Bus database points |
PCD8.SUP-15000EXT | Saia PCD® Supervisor extension, additional 15’000 S-Bus database points |
PCD8.SUP-2500 | Saia PCD® Supervisor basic package incl. S-Bus driver, 2’500 database points |
PCD8.SUP-2500EXT | Saia PCD® Supervisor extension, additional 2’500 S-Bus database points |
PCD8.SUP-2500OPEN | Extend base license, with additional 2’500 open protocol points, (BACnet IP, EIB/KNX IP, LON IP, Modbus IP, M-Bus IP, SNMP) |
PCD8.SUP-500 | Saia PCD® Supervisor basic package incl. S-Bus driver, 500 database points |
PCD8.SUP-5000EXT | Saia PCD® Supervisor extension, additional 5’000 S-Bus database points |
PCD8.SUP-5000OPEN | Extend base license, with additional 5’000 open protocol points, (BACnet IP, EIB/KNX IP, LON IP, Modbus IP, M-Bus IP, SNMP) |
PCD8.SUP-500OPEN | Extend base license, with additional 500 open protocol points, (BACnet IP, EIB/KNX IP, LON IP, Modbus IP, M-Bus IP, SNMP) |
PCD8.SUP-DB-CSV | Extend the capability for the Supervisor, to interact with Microsoft Excel |
PCD8.SUP-DB-SQL | Extend the capability for the supervisor, to communicate with SQL Server |
PCD8.SUP-MNT1 | Saia PCD® Supervisor maintenance upgrade, additional 1 year |
PCD8.SUP-MNT3 | Saia PCD® Supervisor maintenance upgrade, additional 3 year |
PCD8.SUP-MNT5 | Saia PCD® Supervisor maintenance upgrade, additional 5 year |
PCD8.SUP-NAA-ENG | Saia PCD® Supervisor, additional engineering license |
PCD8.SUP-NAA-REN | Saia PCD® Supervisor, annual agreement renewal |
PCD8.SUP-NAA-STK | Saia PCD® Supervisor Starter kit, annual agreement (5 engineers) |
PCD8.SUP-NAA-UPG | Saia PCD® Supervisor, annual agreement upgrade |
PCD8.SUP-OPC | Extend the open protocol points, with OPC client connectivity |
PCD8.VP-BACNET | BACnet driver Driver for up to 2’500 BACnet objects |
PCD8.VP-BACNET10 | BACnet driver Driver for up to 10’000 BACnet objects |
PCD8.VP-BASIC | Visi.Plus Basic – Basic package Data management system, database system, graphical editor, engineering tool, scheduler program, trend and alarm capture, MALM remote alarms via SMS/e-mail, PRT access logging and SBC S-Driver for 10’000 data points (approx. 650 hardware data points) |
PCD8.VP-ESPA | ESPA 4.4.4 – Receive alarms and messages via ESPA protocol to Visi.Plus |
PCD8.VP-GE10 | GE10 – Graphical editor Runtime system, ten additional operator stations |
PCD8.VP-GE2 | GE2 – Graphical editor Runtime system, two additional operator stations |
PCD8.VP-GE5 | GE5 – Graphical editor Runtime system, five additional operator stations |
PCD8.VP-MALM | MALM – Remote alarms via SMS/e-mail (included in Basic and Standard package) |
PCD8.VP-MALMESPA | MALM ESPA 4.4.4 – Remote alarms (sending) via ESPA protocol (add-on option for MALM) |
PCD8.VP-MINI | Visi.Plus Mini – Mini package Data management system, database system, graphical editor, engineering tool, scheduler program, trend and alarm capture and SBC S-Driver for 1’000 data points (approx. 65 hardware data points) |
PCD8.VP-OPC1 | OPC1 – OPC Client Client for 250 data points |
PCD8.VP-OPC2 | OPC2 – OPC Client Client for 1’000 data points |
PCD8.VP-OPC3 | OPC3 – OPC Client Client for 10’000 data points |
PCD8.VP-PCALC | pCalc – Calculation for energy analysis and system monitoring, up to 1’000 formulas with 16 variables each |
PCD8.VP-PCHART | pChart – Trend display tool Each user (1..10) costs a full pChart license (one user included in the Standard package) |
PCD8.VP-PRT | PRT – Access Logging (included in the Basic and Standard package) |
PCD8.VP-SBUS10K | Option for Visi.Plus packages SBC S-Driver for 10’000 additional data points (approx. 650 hardware data points) |
PCD8.VP-SBUS25K | Option for Visi.Plus packages SBC S-Driver for 25’000 additional data points (approx. 1’625 hardware data points) Remark : not possible with the Mini package |
PCD8.VP-SBUS50K | Option for Visi.Plus packages SBC S-Driver for 50’000 additional data points (approx. 3’250 hardware data points) Remark : not possible with the Mini package |
PCD8.VP-STD | Visi.Plus Standard – Standard package Data management system, database system, graphical editor, engineering tool, scheduler program, trend and alarm capture, MALM remote alarms via SMS/e-mail, PRT access logging, pChart trend display, web server 2 HTML5 and SBC S-Driver for 100’000 data points (approx. 6’500 hardware data points) |
PCD8.VP-SWDONGLE | Visi.Plus Software dongle license A software dongle is a file that can be used instead of hardware dongle. The software dongle is specific to a licence and a computer (IP address and hard drive number) |
PCD8.VP-UPGRADE | Visi.Plus Upgrade – Version upgrade according to customer’s Visi.Plus package – version 1.5 to 1.6/1.7 |
PCD8.VP-WA10 | Web-Server 10 based on HTML5 for 10 additional simultaneous connections |
PCD8.VP-WA2 | Web-Server 2 based on HTML5 for 2 additional simultaneous connections |
PCD8.VP-WA5 | Web-Server 5 based on HTML5 for 5 additional simultaneous connections |
PCD8.VP-WA-UPGR | Web-Server Upgrade Upgrade from old Web-Server (WEB) to new (WA) |
PMK-EEM400 | Kit for mounting ALE3/AWD3 energy meters on door cabinet |
Q.NET-5TX | Industrial Ethernet switch, 5 ports 10/100Base-TX, 24 VDC, DIN rail mounting |
Q.NET-8TX | Industrial Ethernet switch, 8 ports 10/100Base-TX, 24 VDC, DIN rail mounting |
Q.NET-CON | Annual license for the “SBC Connectivity Service” portal |
Q.NET-EBW-E100 | Industrial LAN router for VPN connection . |
Q.NET-EBW-H100 | Industrial 3G/HSPA router for VPN connection . |
Q.PS-AD1-2403 | Switch-mode power supply, input 24 VAC, output 24 VDC / 3 A |
Q.PS-AD1-2405 | Switch-mode power supply, input 24 VAC, output 24 VDC / 5 A |
Q.PS-AD2-2402F | Switch-mode power supply, input 115…230 VAC, output 24 VDC / 2.5 A |
Q.PS-AD2-2405F | Switch-mode power supply, input 115…230 VAC, output 24 VDC / 5 A |
Q.PS-AD2-2410F | Switch-mode power supply, input 115…230 VAC, output 24 VDC / 10 A |
Q.PS-AD3-2405F | Switch-mode power supply, single or double-phase, input 230 VAC or 400…500 VAC, output 24 VDC / 5 A |
Q.PS-ADB-2405-1 | Single-phase switch-mode power supply with intelligent battery charger, input 115…230 VAC, output 24 VDC / 5 A |
Q.PS-BL2-2401CH | Compact switch-mode power supply, input 115…230 VAC, output 24 VDC / 1.25 A, net cable 230 VAC with CH-connector |
Q.PS-BL2-2401EU | Compact switch-mode power supply, input 115…230 VAC, output 24 VDC / 1.25 A, net cable 230 VAC type IEC320 |
Q.PS-PEL-2401 | Switch-mode power supply for electrical sub-distributors, input 110…240 VAC, output 24 VDC / 0.9 A |
Q.PS-PEL-2403 | Switch-mode power supply for electrical sub-distributors, input 110…240 VAC, output 24 VDC / 2.8 A |
Q.RCU-A-T | Analogue room control unit, temperature sensor |
Q.RCU-A-TS | Analogue room control unit, temperature sensor and setpoint adjustment |
Q.RCU-A-TSO | Analogue room control unit, temperature sensor, setpoint adjustment and presence-tip-switch |
Q.RCU-A-TSOF | Analogue room control unit, temperature sensor, setpoint adjustment, presence-tip-switch and fan control |
T7460A1001 | Room control unit for PCD7.LRxx, temperature sensor |
T7460B1009 | Room control unit for PCD7.LRxx, temperature sensor and setpoint adjustment |
T7460C1007 | Room control unit for PCD7.LRxx, temperature sensor, setpoint adjustment and override |
T7460D1005 | Room control unit for PCD7.LRxx, temperature sensor, setpoint adjustment and fan speed switch |
T7460F1000 | Room control unit for PCD7.LRxx, temperature sensor, setpoint adjustment, override and fan speed switch |
TR40 | Wall module, temperature sensor, SYLK-Bus interface |
TR40-CO2 | Wall module, temperature and CO2 sensors, SYLK-Bus interface |
TR42 | Wall module with LCD display, temperature sensor, setpoint adjustment, override and fan control, SYLK-Bus interface |
TR42-CO2 | Wall module with LCD display, temperature and CO2 sensors, setpoint adjustment, override and fan control, SYLK-Bus interface |